Enhanced extracorporeal carbon dioxide removal by acidification and metabolic control.

Florio Gaetano, Valsecchi Carlo, Vivona Luigi, Battistin Michele, Colombo Sebastiano M, Cattaneo Emanuele, Protti Ilaria, DI Feliciantonio Marianna, Castelli Gloria, Dondossola Daniele, Biancolilli Osvaldo, Carlin Andrea, Gatti Stefano, Pesenti Antonio M, Zanella Alberto, Grasselli Giacomo

СтатьяПоддержка исследования: вне правительства СШАПеревод пока не подготовлен

Аннотация

BACKGROUND

Extracorporeal carbon dioxide removal (ECCO<inf>2</inf>R) promotes protective ventilation in patients with acute respiratory failure, but devices with high CO<inf>2</inf> extraction capacity are required for clinically relevant impact. This study evaluates three novel low-flow techniques based on dialysate acidification, also combined with renal replacement therapy, and metabolic control.

METHODS

Eight swine were connected to a low-flow (350 mL/min) extracorporeal circuit including a dialyzer with a closed-loop dialysate circuit, and two membrane lungs on blood (ML<inf>b</inf>) and dialysate (ML<inf>d</inf>), respectively. The following 2-hour steps were performed: 1) ML<inf>b</inf>-start (ML<inf>b</inf> ventilated); 2) ML<inf>bd</inf>-start (ML<inf>b</inf> and ML<inf>d</inf> ventilated); 3) HLac (lactic acid infusion before ML<inf>d</inf>); 4) HCl-NaLac (hydrochloric acid infusion before ML<inf>d</inf> combined with renal replacement therapy and reinfusion of sodium lactate); 5) HCl-βHB-NaLac (hydrochloric acid infusion before ML<inf>d</inf> combined with renal replacement therapy and reinfusion of sodium lactate and sodium 3-hydroxybutyrate). Caloric and fluid inputs, temperature, blood glucose and arterial carbon dioxide pressure were kept constant.

RESULTS

The total MLs CO<inf>2</inf> removal in HLac (130±25 mL/min), HCl-NaLac (130±21 mL/min) and HCl-βHB-NaLac (124±18 mL/min) were higher compared with ML<inf>bd</inf>-start (81±15 mL/min, P<0.05) and ML<inf>b</inf>-start (55±7 mL/min, P<0.05). Minute ventilation in HLac (4.3±0.9 L/min), HCl-NaLac (3.6±0.8 L/min) and HCl-βHB-NaLac (3.6±0.8 L/min) were lower compared to ML<inf>b</inf>-start (6.2±1.1 L/min, P<0.05) and ML<inf>bd</inf>-start (5.8±2.1 L/min, P<0.05). Arterial pH was 7.40±0.03 at ML<inf>b</inf>-start and decreased only during HCl-βHB-NaLac (7.35±0.03, P<0.05). No relevant changes in electrolyte concentrations, hemodynamics and significant adverse events were detected.

CONCLUSIONS

The three techniques achieved a significant extracorporeal CO<inf>2</inf> removal allowing a relevant reduction in minute ventilation with a sufficient safety profile.

Для цитирования: Florio Gaetano, Valsecchi Carlo, Vivona Luigi, Battistin Michele, Colombo Sebastiano M, Cattaneo Emanuele, Protti Ilaria, DI Feliciantonio Marianna, Castelli Gloria, Dondossola Daniele, Biancolilli Osvaldo, Carlin Andrea, Gatti Stefano, Pesenti Antonio M, Zanella Alberto, Grasselli Giacomo. Enhanced extracorporeal carbon dioxide removal by acidification and metabolic control.. Minerva anestesiologica. 2023. DOI: 10.23736/s0375-9393.23.17142-2.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.