MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1371/journal.pone.0214161

Медицинская библиотека · PloS one · 2019

Ultrasensitive detection of lipoarabinomannan with plasmonic grating biosensors in clinical samples of HIV negative patients with tuberculosis.

Wood Aaron, Barizuddin Syed, Darr Charles M, Mathai Cherian J, Ball Alexey, Minch Kyle, Somoskovi Akos, Hamasur Beston, Connelly John T, Weigl Bernhard, Andama Alfred, Cattamanchi Adithya, Gangopadhyay Keshab, Bok Sangho, Gangopadhyay Shubhra

Клиническое исследованиеСтатьяМногоцентровое исследованиеПоддержка исследования: вне правительства СШАПеревод в очереди

Аннотация

BACKGROUND

Timely diagnosis of tuberculosis disease is critical for positive patient outcomes, yet potentially millions go undiagnosed or unreported each year. Sputum is widely used as the testing input, but limited by its complexity, heterogeneity, and sourcing problems. Finding methods to interrogate noninvasive, non-sputum clinical specimens is indispensable to improving access to tuberculosis diagnosis and care. In this work, economical plasmonic gratings were used to analyze tuberculosis biomarker lipoarabinomannan (LAM) from clinical urine samples by single molecule fluorescence assay (FLISA) and compared with gold standard sputum GeneXpert MTB/ RIF, culture, and reference ELISA testing results.

METHODS AND FINDINGS: In this study, twenty sputum and urine sample sets were selected retrospectively from a repository of HIV-negative patient samples collected before initiation of anti-tuberculosis therapy. GeneXpert MTB/RIF and culture testing of patient sputum confirmed the presence or absence of pulmonary tuberculosis while all patient urines were reference ELISA LAM-negative. Plasmonic gratings produced by low-cost soft lithography were bound with anti-LAM capture antibody, incubated with patient urine samples, and biotinylated detection antibody. Fluorescently labeled streptavidin revealed single molecule emission by epifluorescence microscope. Using a 1 fg/mL baseline for limit of detection, single molecule FLISA demonstrated good qualitative agreement with gold standard tests on 19 of 20 patients, including accurately predicting the gold-standard-negative patients, while one gold-standard-positive patient produced no observable LAM in urine.

CONCLUSIONS

Single molecule FLISA by plasmonic grating demonstrated the ability to quantify tuberculosis LAM from complex urine samples of patients from a high endemic setting with negligible interference from the complex media itself. Moreover, agreement with patient diagnoses by gold standard testing suggests that single molecule FLISA could be used as a highly sensitive test to diagnose tuberculosis noninvasively.

Для цитирования: Wood Aaron, Barizuddin Syed, Darr Charles M, Mathai Cherian J, Ball Alexey, Minch Kyle, Somoskovi Akos, Hamasur Beston, Connelly John T, Weigl Bernhard, Andama Alfred, Cattamanchi Adithya, Gangopadhyay Keshab, Bok Sangho, Gangopadhyay Shubhra. Ultrasensitive detection of lipoarabinomannan with plasmonic grating biosensors in clinical samples of HIV negative patients with tuberculosis.. PloS one. 2019. DOI: 10.1371/journal.pone.0214161.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.