m+Medelevator.RU
← Поиск публикаций
Molecules (Basel, Switzerland) · 2021

Development and Validation of Liquid Chromatography-Tandem Mass Spectrometry Methods for the Quantification of Cefquinome, Ceftiofur, and Desfuroylceftiofuracetamide in Porcine Feces with Emphasis on Analyte Stability.

СтатьяВалидационное исследованиеНазвание и аннотация: Перевод в очереди
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Rutjens Sofie, Croubels Siska, Baere Siegrid De, Devreese Mathias

Аннотация

Cefquinome and ceftiofur are β-lactam antibiotics used for the treatment of bacterial infections in swine. Although these antimicrobials are administered intramuscularly, the exposure of the gut microbiota to these cephalosporins is not well described. This exposure can contribute to the emergence and spread of antimicrobials in the environment and to the possible spread of antimicrobial resistance genes. To assess the impact of drug administration on the intestinal excretion of these antimicrobials it is essential to measure the amounts of native compound and metabolites in feces. Two (ultra)-high-performance liquid chromatography-tandem mass spectrometry ((U)HPLC-MS/MS) methods were developed and validated, one for the determination of cefquinome and ceftiofur and the other for the determination of ceftiofur residues, measured as desfuroylceftiofuracetamide, in porcine feces. The matrix-based calibration curve was linear from 5 ng g-1 to 1000 ng g-1 for cefquinome (correlation coefficient (r) = 0.9990 ± 0.0007; goodness of fit (gof) = 3.70 ± 1.43) and ceftiofur (r = 0.9979 ± 0.0009; gof = 5.51 ± 1.14) and quadratic from 30 ng g-1 to 2000 ng g-1 for desfuroylceftiofuracetamide (r = 0.9960 ± 0.0020; gof = 7.31 ± 1.76). The within-day and between-day precision and accuracy fell within the specified ranges. Since β-lactam antibiotics are known to be unstable in feces, additional experiments were conducted to adjust the sampling protocol in order to minimize the impact of the matrix constituents on the stability of the analytes. Immediately after sampling, 500 µL of an 8 µg mL-1 tazobactam solution in water was added to 0.5 g feces, to reduce the degradation in matrix.

Предметные рубрики MeSH

ИП Урсолов Владлен Сергеевич

ИНН 500118482352 · ОГРНИП 314500117700049

Реквизиты и контакты