MedElevator Войти в исследования
← Поиск публикаций

DOI 10.3109/14767058.2014.954540

Медицинская библиотека · The journal of maternal-fetal & neonatal medicine : the official journal of the European Association of Perinatal Medicine, the Federation of Asia and Oceania Perinatal Societies, the International Society of Perinatal Obstetricians · 2015

Viewing rate and reproducibility of papillary muscle areas in foetal atrioventricular valves using spatio-temporal image correlation in the rendering mode in congenital heart disease.

Rolo Liliam Cristine, Pietrolucci Maria Elena, Araujo Júnior Edward, Barros Fernanda Silveira Bello, Nardozza Luciano Marcondes Machado, Martina Wellington P, Moron Antonio Fernandes, Arduin Domenico, Rizzo Giuseppe

СтатьяПеревод пока не подготовлен

Аннотация

OBJECTIVE

To assess the viewing rate and reproducibility of areas of the papillary muscles (PMs) of foetal atrioventricular valves using spatio-temporal image correlation (STIC) in the rendering mode in congenital heart disease (CHD).

METHODS

We retrospectively reviewed 40 4D-STIC volume datasets from different foetal CHD cases at a gestational age of 18w6d–35w6d. The following papillary muscles (PMs) were assessed: antero-lateral (MPAL) and postero-medial (MPPM) to the mitral valve and antero-superior (MPAS), inferior (MPI) and septal (MPS) to the tricuspid valve. To assess the valve viewing rate, percentages (%) were used. The concordance correlation coefficient (CCC) was used to assess inter-observer reliability.

RESULTS

Two independent observers concluded that a complete examination of the PMs was impossible in 11 cases, yielding a viewing rate of 72.5%. The complete examination of the PMs of the tricuspid and mitral valves was possible by both examiners in 33/40 (82.5%) and 32/40 (80.0%) cases, respectively. We observed moderate to good inter-observer reliability with CCCs of 0.95, 0.92, 0.97, 0.96 and 0.97 for MPS, MPI, MPAS, MPAL and MPPM, respectively.

CONCLUSION

The viewing rate of PM areas in different CHDs using STIC in the rendering mode was moderate. The inter-observer reproducibility was moderate to good for all PM areas.

Для цитирования: Rolo Liliam Cristine, Pietrolucci Maria Elena, Araujo Júnior Edward, Barros Fernanda Silveira Bello, Nardozza Luciano Marcondes Machado, Martina Wellington P, Moron Antonio Fernandes, Arduin Domenico, Rizzo Giuseppe. Viewing rate and reproducibility of papillary muscle areas in foetal atrioventricular valves using spatio-temporal image correlation in the rendering mode in congenital heart disease.. The journal of maternal-fetal & neonatal medicine : the official journal of the European Association of Perinatal Medicine, the Federation of Asia and Oceania Perinatal Societies, the International Society of Perinatal Obstetricians. 2015. DOI: 10.3109/14767058.2014.954540.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.