m+Medelevator.RU
← Поиск публикаций
The American journal of cardiology · 2013

Hemodynamic impact and outcome of permanent pacemaker implantation following transcatheter aortic valve implantation.

Сравнительное исследованиеСтатьяНазвание и аннотация: Перевод пока не подготовлен
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Biner Simon, Michowitz Yoav, Leshem-Rubinow Eran, Topilsky Yan, Ben-Assa Eyal, Shimiaie Jason, Banai Shmuel, Keren Gad, Steinvil Arie, Finkelstein Ariel

Аннотация

Transcatheter aortic valve implantation (TAVI) frequently requires postprocedural permanent pacemaker (PPM) implantation. We evaluated clinical and hemodynamic impact of PPM after TAVI. Clinical and echocardiographic data were retrospectively analyzed in 230 consecutive patients who underwent TAVI and echocardiography at baseline and after 6 months. Echocardiographic parameters included left ventricular ejection fraction (LVEF), left ventricular (LV) stroke volume, early mitral velocity/annulus velocity ratio (E/e'), right ventricular index of myocardial performance, systolic pulmonary artery pressure (SPAP), and aortic, mitral, and tricuspid regurgitation grades. Clinical outcomes included 2-year survival and cardiovascular and PPM-related event-free survival. The Medtronic CoreValve and Edwards Sapien prosthesis were used in 201 and 29 patients, respectively. PPM was required in 58 patients (25.4%). Two-year and event-free survival rates were similar between patients with and without PPM. At 6 months, patients with PPM demonstrated attenuated improvement in LVEF (-0.9 ± 8.7% vs 2.3 ± 10.8%, respectively, p = 0.03) and LV stroke volume (-2 ± 16 vs 4 ± 10 ml/m(2), respectively, p = 0.015), a trend toward smaller reduction in systolic pulmonary artery pressure (-1 ± 12 vs -6 ± 10 mm Hg, respectively, p = 0.09), and deterioration of right ventricular index of myocardial performance (-3 ± 17% vs 5 ± 26%, respectively, p = 0.05). The differences in post-TAVI aortic, mitral, and tricuspid regurgitation grades were insignificant. In conclusion, PPM implantation after TAVI is associated with reduced LVEF and impaired LV unloading. However, this unfavorable hemodynamic response does not affect the 2-year clinical outcome. The maintenance of clinical benefit appears to be driven by TAVI-related recovery of LV and right ventricular performance that mitigates unfavorable impact of PPM.

Предметные рубрики MeSH

ИП Урсолов Владлен Сергеевич

ИНН 500118482352 · ОГРНИП 314500117700049

Реквизиты и контакты