MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.jbiomech.2012.11.054

Медицинская библиотека · Journal of biomechanics · 2013

In vitro assessment of available coaptation area as a novel metric for the quantification of tricuspid valve coaptation.

Dolensky Joseph R, Casa Lauren D C, Siefert Andrew W, Yoganathan Ajit P

СтатьяПоддержка исследования: вне правительства СШАПеревод пока не подготовлен

Аннотация

Tricuspid regurgitation (TR) is associated with increased mortality in patients undergoing mitral valve repair. In recent decades, TR has been addressed using annuloplasty concomitantly with mitral valve repair by some surgeons. However, repair efficacy and durability are often suboptimal. Increased understanding of tricuspid valve coaptation and the effects of pathological and repair conditions may be useful to inform future repair design. In the present study, we propose a two-dimensional in vitro technique, available coaptation area (ACA), to quantify the area of each tricuspid leaflet available for coaptation. Preliminary results showed that annular dilatation caused a significant (p<0.05) decrease in anterior leaflet ACA (0.92±0.18cm(2)), and combined annular dilatation and papillary muscle (PM) displacement resulted in a significant decrease in posterior leaflet ACA (0.87±0.15cm(2)). Isolated PM displacement did not have a significant effect on ACA, and the septal leaflet showed no changed in ACA under the conditions tested. In addition to quantifying ACA, our technique allows for the detailed mapping of leaflet coaptation, which may be used to reveal specific sites of malcoaptation on each leaflet. Application of the ACA method in future studies may lead to the development of specialized tricuspid repair strategies and annuloplasty ring designs that target specific regions of the tricuspid valve based on underlying pathological conditions.

Для цитирования: Dolensky Joseph R, Casa Lauren D C, Siefert Andrew W, Yoganathan Ajit P. In vitro assessment of available coaptation area as a novel metric for the quantification of tricuspid valve coaptation.. Journal of biomechanics. 2013. DOI: 10.1016/j.jbiomech.2012.11.054.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.