DOI 10.1097/qai.0000000000002002
Brief Report: Real-World Performance and Interobserver Agreement of Urine Lipoarabinomannan in Diagnosing HIV-Associated Tuberculosis in an Emergency Center.
Аннотация
BACKGROUND
The urine lipoarabinomannan (LAM) lateral flow assay is a point-of-care test to diagnose HIV-associated tuberculosis (TB). We assessed the performance of urine LAM in HIV-positive patients presenting to the emergency center and evaluated the interobserver agreement between emergency center physicians and laboratory technologists.
SETTING
A cross-sectional diagnostic study was performed at the emergency center of a district hospital in a high HIV-prevalence community in South Africa.
METHODS
Consecutive HIV-positive adults presenting with ≥1 WHO TB symptom were enrolled over a 16-month period. A urine LAM test was performed at point-of-care by an emergency physician and interpreted independently by 2 physicians. A second test was performed in the laboratory and interpreted independently by 2 laboratory technologists. The reference standard was a positive TB culture or Xpert MTB/RIF test on sputum or appropriate extrapulmonary samples. We compared diagnostic accuracy and reproducibility of urine LAM between point-of-care readers and laboratory readers.
RESULTS
One thousand three hundred eighty-eight samples (median, 3 samples/participant) were sent for TB microbiology tests in 411 participants; 170 had confirmed TB (41.4%). Point-of-care and laboratory-performed urine LAM had similar sensitivity (41.8% vs 42.0%, P = 1.0) and specificity (90.5% vs 87.5%, P = 0.23). Moderate agreement was found between point-of-care and laboratory testing (κ = 0.62), but there was strong agreement between point-of-care readers (κ = 0.95) and between laboratory readers (κ = 0.94). Positive percent agreement between point-of-care and laboratory readers was 68% and negative percent agreement 92%.
CONCLUSION
There is no diagnostic accuracy advantage in laboratory-performed versus point-of-care-performed urine LAM tests in emergency care centers in high-burden settings.
Предметные рубрики MeSH
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.