MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.jvir.2020.05.025

Медицинская библиотека · Journal of vascular and interventional radiology : JVIR · 2020

Transjugular Intrahepatic Portosystemic Shunt Creation Using a Radiofrequency Wire: Prospective Clinical Safety and Feasibility Trial in Cirrhosis.

Farsad Khashayar, Narasimhan Evan, Russell Lori, Kaufman John A

Клиническое исследованиеСтатьяVideo-Audio MediaПеревод пока не подготовлен

Аннотация

PURPOSE: To assess the safety and feasibility of using a radiofrequency (RF) wire for portosystemic shunt creation.

MATERIALS AND

METHODS

Ten patients undergoing elective creation of a transjugular intrahepatic portosystemic shunt (TIPS) or a direct intrahepatic portosystemic shunt (DIPS) were prospectively enrolled. Primary outcomes were the safety and feasibility of RF wire used for the creation of TIPS and DIPS. Median age was 66.5 ± 6.1 years. Causes of liver disease included alcohol (n = 5), nonalcoholic steatohepatitis (n = 2), hepatitis C virus (n = 1), primary biliary cirrhosis (n = 1), autoimmune hepatitis (n = 1). The median score for model for end-stage liver disease was 11 ± 4.3. The Rosch-Uchida TIPS set was used with intravascular ultrasonography guidance in all cases. A 0.035-inch RF wire was used in lieu of the trocar needle through the 5-F TIPS set catheter to create a track between the hepatic vein and the portal vein. All shunts were created using stent grafts.

RESULTS

Technical success rate was 100%. In 7 of 10 patients, portal vein access was achieved with a single pass. A DIPS was created in 2 patients based on anatomic favorability. Median fluoroscopy time was 13.3 ± 3.8 min, and median total procedure time was 102 ± 19 min. The wire passed through parenchyma without subjective deflection. There was 1 case of extracapsular puncture with no clinical consequence. The RF wire was too stiff to curve into the main portal vein, requiring wire exchange in all but 1 case. Mean portosystemic gradient decreased from 13.9 ± 3.3 to 5.9 ± 2.1 mm Hg. No immediate complications were encountered. Shunt patency was 100% at 30 days.

CONCLUSIONS

Creation of TIPS and DIPS using an RF wire was safe and feasible, enabling creation of an intrahepatic track without subjective deflection in cirrhotic patients.

Для цитирования: Farsad Khashayar, Narasimhan Evan, Russell Lori, Kaufman John A. Transjugular Intrahepatic Portosystemic Shunt Creation Using a Radiofrequency Wire: Prospective Clinical Safety and Feasibility Trial in Cirrhosis.. Journal of vascular and interventional radiology : JVIR. 2020. DOI: 10.1016/j.jvir.2020.05.025.