MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1111/aor.70020

Медицинская библиотека · Artificial organs · 2025

Preoperative Atrial Fibrillation Does Not Impact Long-Term Survival and Complications in Left Ventricular Assistance Device Recipients.

Cherbi Miloud, Galand Vincent, Barré Valentin, Groussin Pierre, Dezecot Melvyn, Gautier Paul, Maury Philippe, Delmas Clément, Flecher Erwan, Martins Raphael

СтатьяНаблюдательное исследованиеМногоцентровое исследованиеПеревод пока не подготовлен

Аннотация

INTRODUCTION

A substantial proportion of patients receiving left ventricular assist devices (LVADs) present with pre-existing atrial fibrillation (AF). However, the prognostic significance of AF-particularly regarding overall survival and ventricular arrhythmias (VAs)-remains unclear.

METHODS

Patients included were those from the multicenter ASSIST-ICD observational study. The association between AF and the primary endpoint of all-cause mortality was evaluated using a 1:1 propensity score-matched cohort. Secondary outcomes included cardiovascular and non-cardiac mortality, bleeding, stroke, pump thrombosis, and the occurrence of early (≤ 30 days post-implant) and late VAs.

RESULTS

Among 652 LVAD recipients, 286 patients (43.9%) had a history of AF before LVAD implantation, with a median follow-up of 9.1 months (2.5-22.1). AF patients were older, with higher rates of dilated cardiomyopathy, a history of VAs, and longer heart failure duration. After matching, AF was not associated with higher mortality (HR 0.93 [0.69-1.26]). AF subtype (paroxysmal, persistent, permanent) had no impact on mortality. There were no significant differences in cardiovascular/non-cardiac mortality, bleeding, ischemic stroke, pump thrombosis, or early VAs. However, AF was linked to a higher incidence of late VAs.

CONCLUSION

In this large multicenter study, AF before LVAD implantation was not associated with increased risks of mortality, bleeding, stroke, or pump thrombosis, but was linked to a higher incidence of late VAs. These findings, based on earlier-generation devices, should be interpreted cautiously given the recent adoption of the HeartMate 3, offering improved hemocompatibility. Further studies are needed to identify LVAD patients where AF carries clinical significance and guide optimal management.

Для цитирования: Cherbi Miloud, Galand Vincent, Barré Valentin, Groussin Pierre, Dezecot Melvyn, Gautier Paul, Maury Philippe, Delmas Clément, Flecher Erwan, Martins Raphael. Preoperative Atrial Fibrillation Does Not Impact Long-Term Survival and Complications in Left Ventricular Assistance Device Recipients.. Artificial organs. 2025. DOI: 10.1111/aor.70020.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.