Preliminary Short-Term Results of Supraciliary Ab-Interno MINIject® Implantation Following Failed Filtering Glaucoma Surgery in Primary Open-Angle Glaucoma.

Lüke Jan Niklas, Lüke Vincent, Dietlein Thomas, Wiedemann Johanna, Lappas Alexandra

СтатьяПеревод пока не подготовлен

Аннотация

PURPOSE: To investigate the efficacy of MINIject® (suprachoroidal stent) in lowering intraocular pressure (IOP) in eyes following failed filtering glaucoma surgery.

METHODS

In this single-center retrospective study, 18 patients who had undergone suprachoroidal stent implantation after failed filtering surgery were analyzed. Follow-up was at least 12 months, and surgical success was measured by 12-month postoperative intraocular pressure (IOP), glaucoma medication, and revision surgery (criteria A: IOP < 21 mmHg, IOP reduction >20%, no revision surgery; criteria B: IOP < 18 mmHg, IOP reduction >20%, no revision surgery; criteria C: IOP ≤ 15 mmHg, IOP reduction ≥40%, no repeat surgery).

RESULTS

After a follow-up period of 12 months, the mean IOP decreased from 27.11±5.65 mmHg to 15.94±9.56 mmHg (p<0.01). The median 12-month postoperative IOP was 14.0 mmHg (IQR: 10.0-20.0 mmHg). The probability of surgical success was 66.66% for criteria A and B and 50% for criteria C. The identical success rates for criteria A and B were due to overlapping responder groups in this limited sample. Topical medication was significantly reduced from 4.06±1.08 to 2.13±1.36 (p<0.0001).

CONCLUSION

Supraciliary stent implantation provided an effective and safe treatment option for advanced glaucoma following failed filtering surgery and demonstrated significant intraocular pressure reduction. However, the small sample size limits the generalizability of these findings.

Для цитирования: Lüke Jan Niklas, Lüke Vincent, Dietlein Thomas, Wiedemann Johanna, Lappas Alexandra. Preliminary Short-Term Results of Supraciliary Ab-Interno MINIject® Implantation Following Failed Filtering Glaucoma Surgery in Primary Open-Angle Glaucoma.. Clinical ophthalmology (Auckland, N.Z.). 2025. DOI: 10.2147/opth.s534745.
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.