Radiofrequency in the treatment of primary hyperhidrosis: systematic review and meta-analysis.
Аннотация
PURPOSE: To evaluate, via a systematic review, the effectiveness of radiofrequency (RF) for treatment of primary hyperhidrosis (PH).
METHODS
Experimental or observational studies were included where RF treatment (ablation or microneedling) was performed, comparing the periods before and after treatment.
RESULTS
Nine studies were considered eligible and included for analysis. In seven of nine studies, patients were subjected to RF only, and in two of nine studies RF was compared to video-assisted thoracoscopic sympathectomy (VATS). There was a reduction in the severity of PH in microneedling (three studies, mean difference -1.24, 95% CI -1.44 to -1.03). In a study that performed sympathetic RF ablation there was a greater reduction in PH severity compared to studies that performed microneedling (-2.42, 95% CI -2.55 to -2.29). There was improvement in the quality of life (QoL) after sympathetic RF ablation (two studies, mean difference -15.92, 95% CI -17.61 to -14.24). Regarding the microneedling procedure, there was a lower improvement in QoL, (two studies, -9.0, 95% CI -9.15 to -8.85). One study comparing sympathetic RF ablation with VATS applied the QoL questionnaire, and the VATS showed superior results. One of the two studies comparing compensatory sweating in RF ablation with VATS showed that compensatory hyperhidrosis was higher in VATS; however, the other study did not observe this difference. One study compared the recurrence of symptoms between VATS and RF ablation; symptom recurrence was shown to be higher in RF.
CONCLUSIONS
RF is effective for PH treatment, with superior results obtained with sympathetic ablation compared to microneedling.
Предметные рубрики MeSH
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.