MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.hrthm.2022.03.1220

Медицинская библиотека · Heart rhythm · 2022

Termination of macroreentrant atrial arrhythmias by pacing stimuli without global propagation.

Jain Rahul, Jain Rohit, Barmeda Mamta, Shirazi Jonathan T, Abualsuod Amjad, Miller John M

СтатьяПеревод пока не подготовлен

Аннотация

BACKGROUND

Electrical stimulation during ventricular tachycardia resulting in tachycardia termination without global propagation (TWGP) is a well-recognized phenomenon. However, there is a paucity of literature showing a similar phenomenon in atrial arrhythmias.

OBJECTIVE

The purpose of the study was to evaluate the significance of TWGP in atrial arrhythmias.

METHODS

Electrophysiological studies performed from 2000 to 2019 at Methodist Hospital, Indiana University were reviewed retrospectively. Thirty-four patients were identified in whom stimulation during atrial tachycardia/flutter resulted in TWGP.

RESULTS

Of the 34 patients, 12 (29%) had cavotricuspid isthmus (CTI)-dependent atrial flutter and 22 (71%) had other atrial arrhythmias during which TWGP was seen. Mean age of the population was 53 ± 13 years; and 68% were male. Previous catheter ablation for atrial fibrillation, atrial flutter, or other atrial tachyarrhythmias had been performed in 70.5%, and 44% previously had undergone cardiac surgery involving the atria. Congenital heart disease was present in 20.5%; 3 patients were status post lung transplant. Mean cycle length of atrial arrhythmia in which TWGP was seen was 317 ± 76 ms. The sites at which TWGP was seen reproducibly were highly specific for successful termination of the arrhythmias with radiofrequency energy. The arrhythmia circuits were 12 CTI-dependent atrial flutter, 11 left atrial macroreentrant atrial tachycardia (MRAT), 1 involving both left and right atria, and 8 were other right atrial MRAT.

CONCLUSION

Termination of macroreentrant atrial arrhythmias by pacing stimuli without global propagation identifies a narrow diastolic isthmus at which catheter ablation is highly effective.

Для цитирования: Jain Rahul, Jain Rohit, Barmeda Mamta, Shirazi Jonathan T, Abualsuod Amjad, Miller John M. Termination of macroreentrant atrial arrhythmias by pacing stimuli without global propagation.. Heart rhythm. 2022. DOI: 10.1016/j.hrthm.2022.03.1220.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.