Comparison of self-measured diurnal intraocular pressure profiles using rebound tonometry between primary angle closure glaucoma and primary open angle glaucoma patients.

Tan Shaoying, Baig Nafees, Hansapinyo Linda, Jhanji Vishal, Wei Shihui, Tham Clement C

Сравнительное исследованиеСтатьяПеревод пока не подготовлен

Аннотация

PURPOSE: To document the diurnal intraocular pressure (IOP) profile with rebound tonometry performed by primary glaucoma patients in non-clinic environment.

PATIENTS AND

METHODS

Fifty-three medically-treated eyes of 31 primary angle closure glaucoma (PACG) and 22 primary open angle glaucoma (POAG) patients with no previous eye surgery were recruited. Diurnal IOP was measured 5 times per day at four-hourly intervals from 08:00 to 24:00 for 1 week in patients' study eye using rebound tonometry in a non-clinic environment. The diurnal IOP profiles were compared between PACG and POAG eyes.

RESULTS

For both PACG and POAG eyes, mean patient-measured IOP was highest in the morning, gradually decreased over the course of a day, and was lowest by midnight (p < 0.001). The diurnal IOP fluctuation ± 1 standard deviation (SD), as documented by SD in daily IOP values, was lower in PACG group (1.6 ± 1.1 mmHg) than in POAG group (2.0 ± 1.2 mmHg; p = 0.049). The mean trough IOP ± 1 SD was higher in PACG group (12.9 ± 2.8 mmHg), compared to POAG group (11.5 ± 3.8 mmHg; p = 0.041). The mean IOP level at midnight ± 1 SD in PACG group (14.0 ± 3.2 mmHg) was higher than that in POAG group (12.1 ± 3.7 mmHg; p = 0.013).

CONCLUSIONS

IOP in primary glaucoma patients was highest in the morning, and decreased over the course of a day in non-clinic environment. Treated diurnal IOP fluctuation seemed to be greater in POAG than PACG eyes.

Для цитирования: Tan Shaoying, Baig Nafees, Hansapinyo Linda, Jhanji Vishal, Wei Shihui, Tham Clement C. Comparison of self-measured diurnal intraocular pressure profiles using rebound tonometry between primary angle closure glaucoma and primary open angle glaucoma patients.. PloS one. 2017. DOI: 10.1371/journal.pone.0173905.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.