MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.ophtha.2016.05.026

Медицинская библиотека · Ophthalmology · 2016

Pattern of Visual Field Loss in Primary Angle-Closure Glaucoma Across Different Severity Levels.

Atalay Eray, Nongpiur Monisha E, Yap Sae Cheong, Wong Tina T, Goh David, Husain Rahat, Perera Shamira A, Aung Tin

СтатьяПоддержка исследования: вне правительства СШАПеревод пока не подготовлен

Аннотация

PURPOSE: To investigate the patterns of visual field (VF) defects in primary angle-closure glaucoma (PACG) across different severity levels and to assess hemifield differences within each severity level.

DESIGN

Cross-sectional study.

PARTICIPANTS

Three hundred four patients diagnosed with PACG were recruited from glaucoma clinics at a Singapore hospital.

METHODS

Point-wise total deviation values were recorded from the static automated perimetry (Swedish interactive threshold algorithm standard program 24-2; Humphrey model 750 [Carl Zeiss Meditec, Dublin, CA]) printouts. Patients were excluded if they had unreliable VFs (fixation losses >33% and false-positive responses >15%), had undergone only 10-2 VF testing, had VF defects not typical of glaucoma, or had undergone cataract extraction. Mild, moderate, and severe VF loss were defined by a mean deviation of -6.00 dB or more, -6.01 to -12.00 dB, and -12.01 dB or less, respectively. Each hemifield was divided into regions according to glaucoma hemifield test sectors. The average mean deviation (MD) of each region was obtained using total deviation values.

MAIN OUTCOME MEASURES: Between- and within-hemifield differences of the regions across the severity levels.

RESULTS

After excluding ineligible cases, 249 patients with PACG were included in the analysis. Mean age of the patients was 65.7±8.6 years, with a 1:1 gender ratio. The number of patients who had mild, moderate, and severe VFs was 72 (28.9%), 78 (31.3%), and 99 (39.8%), respectively. For between-hemifield comparisons, all regions in the superior hemifield had worse MDs compared with their counterparts in the inferior hemifield across the severity spectrum. Likewise, for within-hemifield comparisons, MDs of the regions gradually worsened with increasing distance from the fixation point.

CONCLUSIONS

In this group of clinic-based PACG patients, the superior hemifield was found to be affected more severely than the inferior hemifield, and the differences between them increased with worsening disease severity. The damage was consistently more pronounced in the nasal area.

Для цитирования: Atalay Eray, Nongpiur Monisha E, Yap Sae Cheong, Wong Tina T, Goh David, Husain Rahat, Perera Shamira A, Aung Tin. Pattern of Visual Field Loss in Primary Angle-Closure Glaucoma Across Different Severity Levels.. Ophthalmology. 2016. DOI: 10.1016/j.ophtha.2016.05.026.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.