Fraser Kelly, Hubbs Ann, Yanamala Naveena, Mercer Robert R, Stueckle Todd A, Jensen Jake, Eye Tracy, Battelli Lori, Clingerman Sidney, Fluharty Kara, Dodd Tiana, Casuccio Gary, Bunker Kristin, Lersch Traci L, Kashon Michael L, Orandle Marlene, Dahm Matthew, Schubauer-Berigan Mary K, Kodali Vamsi, Erdely Aaron

СтатьяПоддержка правительства СШАПеревод пока не подготовлен

Аннотация

BACKGROUND

Multi-walled carbon nanotubes and nanofibers (CNT/F) have been previously investigated for their potential toxicities; however, comparative studies of the broad material class are lacking, especially those with a larger diameter. Additionally, computational modeling correlating physicochemical characteristics and toxicity outcomes have been infrequently employed, and it is unclear if all CNT/F confer similar toxicity, including histopathology changes such as pulmonary fibrosis. Male C57BL/6 mice were exposed to 40 µg of one of nine CNT/F (MW #1-7 and CNF #1-2) commonly found in exposure assessment studies of U.S. facilities with diameters ranging from 6 to 150 nm. Human fibroblasts (0-20 µg/ml) were used to assess the predictive value of in vitro to in vivo modeling systems.

RESULTS

All materials induced histopathology changes, although the types and magnitude of the changes varied. In general, the larger diameter MWs (MW #5-7, including Mitsui-7) and CNF #1 induced greater histopathology changes compared to MW #1 and #3 while MW #4 and CNF #2 were intermediate in effect. Differences in individual alveolar or bronchiolar outcomes and severity correlated with physical dimensions and how the materials agglomerated. Human fibroblast monocultures were found to be insufficient to fully replicate in vivo fibrosis outcomes suggesting in vitro predictive potential depends upon more advanced cell culture in vitro models. Pleural penetrations were observed more consistently in CNT/F with larger lengths and diameters.

CONCLUSION

Physicochemical characteristics, notably nominal CNT/F dimension and agglomerate size, predicted histopathologic changes and enabled grouping of materials by their toxicity profiles. Particles of greater nominal tube length were generally associated with increased severity of histopathology outcomes. Larger particle lengths and agglomerates were associated with more severe bronchi/bronchiolar outcomes. Spherical agglomerated particles of smaller nominal tube dimension were linked to granulomatous inflammation while a mixture of smaller and larger dimensional CNT/F resulted in more severe alveolar injury.

Для цитирования: Fraser Kelly, Hubbs Ann, Yanamala Naveena, Mercer Robert R, Stueckle Todd A, Jensen Jake, Eye Tracy, Battelli Lori, Clingerman Sidney, Fluharty Kara, Dodd Tiana, Casuccio Gary, Bunker Kristin, Lersch Traci L, Kashon Michael L, Orandle Marlene, Dahm Matthew, Schubauer-Berigan Mary K, Kodali Vamsi, Erdely Aaron. Histopathology of the broad class of carbon nanotubes and nanofibers used or produced in U.S. facilities in a murine model.. Particle and fibre toxicology. 2021. DOI: 10.1186/s12989-021-00440-z.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.