MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1097/iop.0b013e3181b1e526

Медицинская библиотека · Ophthalmic plastic and reconstructive surgery · 2009

Comparison of pain scores with 30-gauge and 32-gauge needles for periocular botulinum toxin type a injections.

Yomtoob David E, Dewan Mohit A, Lee Michael S, Harrison Andrew R

Сравнительное исследованиеСтатьяРандомизированное исследованиеПоддержка исследования: вне правительства СШАПеревод пока не подготовлен

Аннотация

PURPOSE: To determine whether a 32-gauge needle can reduce the pain associated with periocular injections of botulinum toxin type A compared with 30-gauge needles.

METHODS

In this prospective, randomized, masked study, 30 patients received bilateral periocular injections of botulinum toxin type A for benign essential blepharospasm. For each patient, a 30-gauge needle was used on one side of the face, and a 32-gauge needle was used on the other side. Equal number of injections and equal amounts of botulinum toxin type A at each injection site were administered on each side of the face. Patients were then asked to rate their pain level on each side of the face, using a standardized 11-point visual analogue pain scale.

RESULTS

The average pain score was 4.38 +/- 2.02 for 30-gauge needles and 3.98 +/- 1.65 for 32-gauge needles. Statistical analysis via Mann-Whitney U test confirmed the null hypothesis that no statistical difference in pain level existed between the 2 needle sizes.

CONCLUSIONS

There is no difference in perceived pain when comparing periocular botulinum toxin type A injections with 30- and 32-gauge needles. In addition, smaller gauge needles require special order and result in greater cost. The authors recommend continued use of 30-gauge needles for botulinum toxin injection in the office setting.

Для цитирования: Yomtoob David E, Dewan Mohit A, Lee Michael S, Harrison Andrew R. Comparison of pain scores with 30-gauge and 32-gauge needles for periocular botulinum toxin type a injections.. Ophthalmic plastic and reconstructive surgery. 2009. DOI: 10.1097/iop.0b013e3181b1e526.