Orbit (Amsterdam, Netherlands) · 2009
Videonystagmography to assess eyelid dynamic disorders.
СтатьяПоддержка исследования: вне правительства СШАНазвание и аннотация: Перевод пока не подготовлен
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Casse Guillaume, Adenis Jean-Paul, Sauvage Jean-Pierre, Robert Pierre-Yves
Аннотация
OBJECTIVES: Apply a videonystagmography (VNG) device to study indirectly blinking in patients with essential blepharospasm.
PATIENTS AND METHODS: A VNG device was used to study the pupillary occlusion. It was recorded and analyzed as indirect parameters of blinking in 23 essential blepharospasm on day 0, month 1, and month 3 following botulinum toxin injection using VNG.
RESULTS: Botulinum toxin significantly reduced pupillary occlusions (PO) frequency (9.6 PO/min on D0 and 4.7 PO/min on M1 (p = 0.004), and average PO time (0.95 sec on D0 and 0.58 sec on M1 (p = 0.03) for PO higher than 0.3 sec. On the other hand, it does not have any action on frequency (32.4 PO/min on D0 and 31.3 PO/min on M1 (p = 0.7) and average PO time (0.16 sec on D0 and 0.15 sec on M1 (p = 0.4) of PO lower than 0.3 sec.
CONCLUSION: Video acquisition computer-assisted makes it possible to measure blinking parameters indirectly in real time and to assess essential blepharospasm objectively. The protocol analysis of PO is attractive for indirect analysis of blinking.
PATIENTS AND METHODS: A VNG device was used to study the pupillary occlusion. It was recorded and analyzed as indirect parameters of blinking in 23 essential blepharospasm on day 0, month 1, and month 3 following botulinum toxin injection using VNG.
RESULTS: Botulinum toxin significantly reduced pupillary occlusions (PO) frequency (9.6 PO/min on D0 and 4.7 PO/min on M1 (p = 0.004), and average PO time (0.95 sec on D0 and 0.58 sec on M1 (p = 0.03) for PO higher than 0.3 sec. On the other hand, it does not have any action on frequency (32.4 PO/min on D0 and 31.3 PO/min on M1 (p = 0.7) and average PO time (0.16 sec on D0 and 0.15 sec on M1 (p = 0.4) of PO lower than 0.3 sec.
CONCLUSION: Video acquisition computer-assisted makes it possible to measure blinking parameters indirectly in real time and to assess essential blepharospasm objectively. The protocol analysis of PO is attractive for indirect analysis of blinking.