MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1002/ccd.27340

Медицинская библиотека · Catheterization and cardiovascular interventions : official journal of the Society for Cardiac Angiography & Interventions · 2017

Transcatheter aortic valve replacement for stenotic bicuspid aortic valves: Systematic review and meta analyses of observational studies.

Reddy Gautam, Wang Zhen, Nishimura Rick A, Greason Kevin L, Yoon Sung-Han, Makkar Raj R, Holmes David R

СтатьяМетаанализСистематический обзорПеревод пока не подготовлен

Аннотация

OBJECTIVE

The aim of this study was to perform a systematic review and meta-analyses of observational studies of transcatheter aortic valve replacement (TAVR) for bicuspid aortic valve stenosis (BcAV).

BACKGROUND

TAVR for BcAV stenosis has been associated with an increased incidence of paravalvular leaks, valve malposition, pacemaker placement and all-cause mortality. The conclusions drawn have been limited by small sample sizes. The use of TAVR for BcAV stenosis remains controversial.

METHODS

We searched multiple databases from the inception of the databases through September 30, 2016 for studies of TAVR for BcAV stenosis. We included all observational studies with more than one patient and at least 1 month of outcomes.

RESULTS

We analyzed 13 observational studies with 758 patients. Meta analyses showed device success rate of 95% [95% confidence interval (CI) 90.2% to 98.5%] and an early safety event in 16.9% [95% CI 12.2% to 22%]. At 30 days, moderate to severe paravalvular leak was seen in 12.2% [95% CI 3.1% to 24.8%] and new pacemaker implantation in 17.9% [95% CI 14.2% to 22%]. All-cause mortality was 3.7% [95% CI 2.1% to 5.6%], which should be viewed in the context of an STS PROM of 5.0%.

CONCLUSIONS

This analysis suggests that TAVR for BcAV is not associated with excess mortality. The incidence of paravalvular leaks and pacemaker implant is increased compared to tricuspid aortic valve cohorts undergoing TAVR, and operators should weigh these potential complications against the clinical benefit provided by TAVR for BcAV patients at high risk for surgical valve replacement.

Для цитирования: Reddy Gautam, Wang Zhen, Nishimura Rick A, Greason Kevin L, Yoon Sung-Han, Makkar Raj R, Holmes David R. Transcatheter aortic valve replacement for stenotic bicuspid aortic valves: Systematic review and meta analyses of observational studies.. Catheterization and cardiovascular interventions : official journal of the Society for Cardiac Angiography & Interventions. 2017. DOI: 10.1002/ccd.27340.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.