Catheterization and cardiovascular interventions : official journal of the Society for Cardiac Angiography & Interventions · 2015

Comparison of multislice computed tomography findings between bicuspid and tricuspid aortic valves before and after transcatheter aortic valve implantation.

Сравнительное исследованиеСтатьяНаблюдательное исследованиеНазвание и аннотация: Перевод пока не подготовлен
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Watanabe Yusuke, Chevalier Bernard, Hayashida Kentaro, Leong Tora, Bouvier Erik, Arai Takahide, Farge Arnaud, Hovasse Thomas, Garot Philippe, Cormier Bertrand, Morice Marie-Claude, Lefèvre Thierry

Аннотация

AIMS: This study sought to compare the multislice computed tomography (MSCT) characteristics of bicuspid aortic valves (BAV) and tricuspid aortic valves (TAV) before and after implantation of the CoreValve (Medtronic, Santa Rosa, California) or the Edwards SapienXT (Edwards Lifesciences, Irvine, CA).

METHODS AND RESULTS: From March 2009 to March 2013, a total of 67 TAVI patients who had both pre- and post-procedural MSCT were studied. Eleven patients underwent TAVI in BAV with the CoreValve (n = 6) or SapienXT (n = 5) and 56 patients underwent TAVI in TAV with the CoreValve (n = 38) or SapienXT (n = 18). The BAV group was similar to the TAV group except for a higher pre-procedural mean pressure gradient (53.1 ± 17.4 vs. 48.8 ± 20.4 mm Hg, P = 0.03), a larger annulus perimeter (89.3 ± 9.0 vs. 81.8 ± 8.1 mm, P = 0.03) and a higher aortic valve calcium volume (1262.7 ± 396.0 vs. 556.4 ± 461.9 mm(3) , P < 0.01). In the CoreValve group, post-procedural mean pressure gradient was significantly higher in the BAV group (11.0 ± 2.6 vs. 8.2 ± 2.8 mm Hg, P = 0.04) and a smaller valve area/pre-annulus area ratio was observed at each level of the prosthesis (base of the stent frame 81.7% ± 14.9% vs. 94.7% ± 15.0%, P = 0.06, annulus level 74.3% ± 16.7% vs. 89.9% ± 10.5%, P = 0.03, leaflet level 64.6% ± 13.1% vs. 81.2% ± 13.2%, P < 0.01). This was not observed in the Edwards group.

CONCLUSIONS: Compared to TAV, patients with BAV have higher gradients, larger annulus perimeters and more calcified valves. Higher post procedural gradient and valve underexpansion were frequently observed after CoreValve implantation. Further MSCT study is required to demonstrate the efficacy of TAVI in BAV.