MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1080/15298668791384986

Медицинская библиотека · American Industrial Hygiene Association journal · 1987

Microscopes and ocular infections.

Olcerst R B

СтатьяПеревод пока не подготовлен

Аннотация

Environmental microbial assays of industrial microscope eyepieces were conducted following reports of multiple intershift ocular infections. Pathogenic Staphylococcus aureus was identified among the microorganisms cultured. This paper suggests that direct contact with industrial microscope eyepieces provides a potentially significant route of transmission of both bacterial and viral ocular infections. An industrial hygiene ocular health questionnaire was distributed to a first and second shift manufacturing operation to assess the incidence of ocular infections. These data were compared to the questionnaire responses of 122 control manufacturing workers who did not use microscopes. Based on self-reporting by employees, those who used microscopes were found to have statistically significant incidence of sites and conjunctivitis that was 8.3 times that of the control group. Sterilization of eyepieces by ethylene oxide, formaldehyde and isopropyl alcohol were considered, but ultimately rejected. These biocides were found respectively to damage ocular lens coatings, contribute to volatile organic emissions, or be ineffective against spore-forming bacteria. This article presents a detailed evaluation of a commercially available ultraviolet sanitization unit (manufactured by the King Bactostat Corp., 7115 Armistad Street, El Paso, TX 79912). This ultraviolet disinfection process proved to be rapid and emission free; it also yielded eyepieces free of residual chemical biocides that have the potential for ocular irritation. Field tests involving 60 eyepieces demonstrated effective disinfection by a Chi-Square statistical comparison, at values greater than 95% confidence level, as compared to unirradiated eyepieces.

Для цитирования: Olcerst R B. Microscopes and ocular infections.. American Industrial Hygiene Association journal. 1987. DOI: 10.1080/15298668791384986.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.