The intraocular lens position in high myopia eyes.

Wang Ziyi, He Siqing, Ding Ning, Xin Chen, Dong Zhe

СтатьяПеревод пока не подготовлен

Аннотация

PURPOSE: To explore the positional relationship between intraocular lens (IOL) and crystalline lens (CLL) by anterior segment optical coherence tomography (AS-OCT) in high myopia complicated with cataract eyes.

STUDY

DESIGN

Retrospective and consecutive study.

METHODS

Patients who had undergone phacoemulsification with IOL implantation were reviewed. Exclusion criteria were any ocular history that could have affected the zonules, poor pupil dilation and intra- or post- operative complications. The magnitude and direction of tilt and decentration of CLL and IOL, CLL thickness (LT), anterior chamber depth (ACD) and axial length (AL) were measured.

RESULTS

Fifty eyes without high myopia (EM group) and 73 high myopia eyes (HM group) were recruited. The magnitude of tilt and decentration of CLL was significantly different between the HM and EM group (ptilt HM vs. EM <0.01, pdecentration HM vs. EM <0.01). In terms of the decentration, the magnitude of IOL was significantly higher than of CLL in both the HM and EM groups (p HM < 0.01; p EM=0.043). Multivariate analysis showed that only the alignment of CLL was related with the position of IOL in both group (R2 tilt EM=0.237, p tilt EM < 0.01, R2 decentration EM=0.097, p tilt EM=0.042; R2 tilt HM=0.476, p tilt HM < 0.01, R2 decentration HM=0.359, p tilt HM < 0.01).

CONCLUSIONS

Alignment of CLL in high myopia eyes determines the position of the IOL. Moreover, the IOL in high myopia was more decentrated, while this discrepancy did not reach a level that would compromise visual quality, it needs to be taken into consideration.

Для цитирования: Wang Ziyi, He Siqing, Ding Ning, Xin Chen, Dong Zhe. The intraocular lens position in high myopia eyes.. Japanese journal of ophthalmology. 2026. DOI: 10.1007/s10384-026-01327-2.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.