m+Medelevator.RU
← Поиск публикаций
Artificial intelligence in medicine · 2024

Abnormal recognition-assisted and onset-offset aware network for pathological wearable ECG delineation.

СтатьяПоддержка исследования: вне правительства СШАНазвание и аннотация: Перевод пока не подготовлен
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Zhang Yue, Lai Jiewei, Zhao Chenyu, Wang Jinliang, Yan Yong, Chen Mingyang, Ji Lei, Guo Jun, Han Baoshi, Shi Yajun, Chen Yundai, Yang Wei, Feng Qianjin

Аннотация

Electrocardiogram (ECG) delineation is essential to the identification of abnormal cardiac status, especially when ECG signals are remotely monitored with wearable devices. The complexity and diversity of cardiac conditions generate numerous pathological ECG patterns, not only requiring the recognition of normal ECG but also addressing an extensive range of abnormal ECG patterns, posing a challenging task. Therefore, we propose an abnormal recognition-assisted network to integrate supplementary information on diverse ECG patterns. Simultaneously, we design an onset-offset aware loss to enhance precise waveform localization. Specifically, we establish a two-branch framework where ECG delineation serves as the target task, producing the final segmentation results. Additionally, the abnormal recognition-assisted network serves as an auxiliary task, extracting multi-label pathological information from ECGs. This joint learning approach establishes crucial correlations between ECG delineation and associated ECG abnormalities. The correlations enable the model to demonstrate sufficient generalization in the presence of diverse abnormal ECG patterns. Besides, onset-offset aware loss focuses intensively on wave onsets and offsets by applying biased weights to various waveform positions. This approach ensures a focus on precise localization, facilitating seamless integration into cross-entropy loss function. A large-scale wearable 12-lead dataset containing 4,913 signals is collected, offering an extensive range of ECG data for model training. Results demonstrate that our method achieves outstanding performance on two test datasets, attaining sensitivity of 94.97% and 94.27% and an error tolerance lower than 20 ms. Furthermore, our method is effective for various aberrant ECG signals, including ST-segment changes, atrial premature beats, and right and left bundle branch blocks.

Предметные рубрики MeSH

ИП Урсолов Владлен Сергеевич

ИНН 500118482352 · ОГРНИП 314500117700049

Реквизиты и контакты