Eye & contact lens · 2018
Comparison of Different Measurement Tools and Dimensional Parameters of Pterygium to Investigate its Impact on Refractive Indices and Ocular Aberrations.
Сравнительное исследованиеСтатьяНазвание и аннотация: Перевод пока не подготовлен
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Gumus Koray, Guven Aysegul, Altinkaynak Miray, Keskin Merve
Аннотация
OBJECTIVES: The aim of this study was to compare different measurement tools and parameters, including a new computer-assisted image processing technique for the quantitative analysis of the percentage of pterygium on the corneal surface, horizontal/vertical lengths obtained using slitlamp beam and surgical compass.
METHODS: A total of 21 pterygia of 17 patients were included in the study. The pterygia were measured by three different methods: a slitlamp beam, a surgical compass, and a new computer-assisted image processing method. Refractive indices and higher-order aberrations were analyzed in all cases.
RESULTS: The new computer-assisted image processing technique revealed excellent intraclass correlation coefficients for intraobserver and interobserver reliability (0.999 and 0.995, respectively). However, horizontal and vertical lengths revealed more deviation between the measurements obtained with slitlamp beam and surgical compass. Although uncorrected visual acuity did not show any significant correlation between horizontal and vertical lengths of pterygia measured by either slitlamp beam or surgical compass, it was correlated with the digital pterygium ratio (rho, 0.462; P=0.035). All ocular aberration (total, higher-order, coma, trefoil, quatrefoil, spherical, and higher-order astigmatism) Root-mean-square values more strongly correlated with higher percentage values of pterygium that covers the cornea, measured by the new computer-assisted image processing technique.
CONCLUSION: The percentage of pterygium covering the corneal surface seems to be more associated with the pterygium-related visual disturbances than with horizontal and vertical lengths measured by conventional techniques. Moreover, the new computer-assisted image processing technique can accurately and reliably measure the percentage extension of pterygium on cornea.
METHODS: A total of 21 pterygia of 17 patients were included in the study. The pterygia were measured by three different methods: a slitlamp beam, a surgical compass, and a new computer-assisted image processing method. Refractive indices and higher-order aberrations were analyzed in all cases.
RESULTS: The new computer-assisted image processing technique revealed excellent intraclass correlation coefficients for intraobserver and interobserver reliability (0.999 and 0.995, respectively). However, horizontal and vertical lengths revealed more deviation between the measurements obtained with slitlamp beam and surgical compass. Although uncorrected visual acuity did not show any significant correlation between horizontal and vertical lengths of pterygia measured by either slitlamp beam or surgical compass, it was correlated with the digital pterygium ratio (rho, 0.462; P=0.035). All ocular aberration (total, higher-order, coma, trefoil, quatrefoil, spherical, and higher-order astigmatism) Root-mean-square values more strongly correlated with higher percentage values of pterygium that covers the cornea, measured by the new computer-assisted image processing technique.
CONCLUSION: The percentage of pterygium covering the corneal surface seems to be more associated with the pterygium-related visual disturbances than with horizontal and vertical lengths measured by conventional techniques. Moreover, the new computer-assisted image processing technique can accurately and reliably measure the percentage extension of pterygium on cornea.