Comparison of clinical outcomes and vault between two types of posterior phakic intraocular lenses in correction of myopia and myopic astigmatism.

Chingan Alexandre, Maftouhi Adil El, Gobeaut M, Kaim Pauline El, Baudouin Christophe, Trinh Liem

СтатьяСравнительное исследованиеПеревод пока не подготовлен

Аннотация

PurposeTo compare refractive and clinical outcomes of two posterior chamber phakic intraocular lenses (pIOLs) for correction of myopia and myopic astigmatism. To evaluate the vault and its variance for the phakic lenses by anterior segment optical coherence tomography (AS-OCT) and ultrasound biomicroscopy (UBM).SettingQuinze-Vingts National Ophthalmology Hospital, Paris, France.Designretrospective case seriesMethodsPatients received an Implantable Collamer Lens (V5 EVO + ICL, Staar surgical AG, Switzerland) or Intraocular Phakic Contact Lens (V2.0 IPCL Caregroup Sight Solution, India). AS-OCT, optical biometry and corneal topography were performed to measure biometric parameters and evaluate post-operative vault.Results12 eyes received an ICL and 14 eyes an IPCL. At 12 months postoperatively, the mean UDVAs were 0.06 ± 0.18 logMAR and 0.16 ± 0.23 logMAR in the ICL and IPCL groups, respectively (p = 0.30). No eye lost CDVA in either group. By AS-OCT, the mean vault was 335.33 ± 165.83 μm and 532.64 ± 167.25 μm in the ICL and IPCL groups, respectively (p = 0.006). By UBM, the mean vault was 355.6 ± 136.6 μm and 509.3 ± 180.79 μm in the ICL and IPCL groups, respectively (p = 0.041).ConclusionsICL and IPCL offer similar refractive and clinical outcomes. IPCL tends to display a more consistent vault with less variation from one patient to another.

Для цитирования: Chingan Alexandre, Maftouhi Adil El, Gobeaut M, Kaim Pauline El, Baudouin Christophe, Trinh Liem. Comparison of clinical outcomes and vault between two types of posterior phakic intraocular lenses in correction of myopia and myopic astigmatism.. European journal of ophthalmology. 2025. DOI: 10.1177/11206721251323642.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.