MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.ajo.2025.03.017

Медицинская библиотека · American journal of ophthalmology · 2025

Comparison of Two-Year Clinical and Patient-Reported Outcome Measures Between Acrysof IQ and Clareon PanOptix Multifocal Intraocular Lenses.

Tuuminen Raimo, Jeon Sohee

СтатьяСравнительное исследованиеПеревод пока не подготовлен

Аннотация

PURPOSE: To compare the 2-year clinical and patient-reported outcome measures of PanOptix multifocal intraocular lenses (MIOLs) based on the lens material.

DESIGN

Retrospective matched cohort study.

METHODS

A comparison between patients who had undergone bilateral operation with Acrysof IQ versus Clareon PanOptix MIOLs was done by 1-to-1 matching of age, axial length, mean keratometry, and corneal astigmatism. A total of 122 eyes of 122 patients in each group were studied. Main outcome measures analyzed included uncorrected near visual acuity (UNVA) and uncorrected distance visual acuity (UDVA), prediction error in spherical equivalent and postoperative refraction stability, glistening, subsurface nano-glistening (SSNG), Nd:YAG laser posterior capsulotomy rates, the area under the log contrast sensitivity function (AULCSF) under photopic and mesopic conditions, Strehl ratio, and area ratio. Patient-reported outcome measures such as dysphotopsia and modified spectacle-independent Visual Function Index (VF)-14 questionnaire scores were collected at 2 years.

RESULTS

Throughout the study period, comparable UNVA, UDVA, and refractive stability were observed between the groups, except for better UNVA among eyes with Clareon than among eyes with Acrysof IQ at 2 years (0.00 ± 0.02 vs 0.02 ± 0.04, P < .001). Clareon implantation resulted in better photopic (1.47 ± 0.19 vs 1.38 ± 0.21 logCWeber units; P < .001), and mesopic (1.16 ± 0.22 vs 1.06 ± 0.19 logCWeber units; P < .001) AULCSF, lower prevalence of glistening (0% vs 88%, P < .001) and SSNG (0% vs 26%, P < .001) and cumulative Nd:YAG laser capsulotomy rates (hazard ratio = 0.632; 95% CI = 0.482-0.830, P < .001) when compared to those with Acrysof IQ. No differences were observed in the incidence of clinically significant glare or halos, but the incidence of starburst (5% vs 16%, P = .002) tended to favor Clareon over Acrysof IQ. Modified VF-14 questionnaire scores were greater for Clareon than Acrysof IQ (93.4 ± 10.3 vs 90.4 ± 13.6 points, P < 0.001). A multivariable regression analysis showed that patient age (beta = -0.394, P < .001; beta = -0.352, P < .001) and glistening grade (beta = -0.163, P = .010; beta = -0.232, P < .001) remained significantly associated with the photopic and mesopic AULCSF, respectively. Furthermore, higher glistening grade (r = -0.144, P = .003; beta = -1.771, P = .001 when age and sex adjusted) were associated with worse modified VF-14 questionnaire scores.

CONCLUSIONS

Clareon PanOptix outperformed Acrysof IQ PanOptix in visual quality and spectacle-independent visual function, potentially resulting from a lower prevalence of glistening.

Для цитирования: Tuuminen Raimo, Jeon Sohee. Comparison of Two-Year Clinical and Patient-Reported Outcome Measures Between Acrysof IQ and Clareon PanOptix Multifocal Intraocular Lenses.. American journal of ophthalmology. 2025. DOI: 10.1016/j.ajo.2025.03.017.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.