MedElevator Войти в исследования
← Поиск публикаций

DOI 10.3928/1081597x-20250204-02

Медицинская библиотека · Journal of refractive surgery (Thorofare, N.J. : 1995) · 2025

Clinical Outcomes of a Refractive Extended Depth of Focus Intraocular Lens.

Orbegozo Javier, Pérez Angelica, Basterra Iñaki, Noguera Helena, Díaz Sergio, González Laura, Lauzirika Gorka, Piñero David P

СтатьяНаблюдательное исследованиеПеревод пока не подготовлен

Аннотация

PURPOSE: To evaluate the clinical and patient-reported outcomes of the toric version of a refractive extended depth of focus intraocular lens (IOL).

METHODS

This was a prospective observational study including 26 eyes of 26 patients (age range: 58 to 88 years) who underwent cataract surgery with implantation of the LuxSmart toric IOL (Bausch & Lomb GmbH). Changes in distance, intermediate (80 cm), and near (40 cm) visual acuities, manifest refraction, defocus curve, distance photopic contrast sensitivity (CSV-1000 test), and patient-reported outcomes (Catquest-9SF questionnaire) were evaluated during a 3-month follow-up.

RESULTS

Mean 3-month postoperative uncorrected distance, corrected distance, distance-corrected intermediate, and distance-corrected near visual acuities of 0.10 ± 0.11, 0.03 ± 0.08, 0.06 ± 0.13, and 0.38 ± 0.22 logarithm of the minimum angle of resolution (logMAR) were found, respectively. Uncorrected and corrected distance visual acuity improved significantly with surgery (P < .001). In the defocus curve, mean visual acuity was 0.30 logMAR or better for defocus between +0.50 and -2.00 D, without significant changes during the follow-up (P ⩾ .071). The postoperative spherical equivalent was within ±0.50 and ±1.00 diopters (D) in 92% and 96% of eyes, respectively. Surgically induced astigmatism prediction error ranged between -0.37 and 0.80 D, with a mean value of 0.11 ± 0.28 D. Mean 3-month postoperative contrast sensitivity was within or close to the upper limit of the normality range for most spatial frequencies. Mean 3-month postoperative overall Rasch calibrated Catquest score was -1.68 ± 1.04, with 96.2% of patients satisfied with the vision achieved. IOL rotations of 5º or less were observed in 92.3% of eyes.

CONCLUSIONS

The toric extended depth of focus IOL evaluated provides a good distance and intermediate functional vision in eyes with preexisting corneal astigmatism, with functional near visual performance for most patients. [J Refract Surg. 2025;41(3):e238-e247.].

Для цитирования: Orbegozo Javier, Pérez Angelica, Basterra Iñaki, Noguera Helena, Díaz Sergio, González Laura, Lauzirika Gorka, Piñero David P. Clinical Outcomes of a Refractive Extended Depth of Focus Intraocular Lens.. Journal of refractive surgery (Thorofare, N.J. : 1995). 2025. DOI: 10.3928/1081597x-20250204-02.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.