MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1186/s12886-025-03856-9

Медицинская библиотека · BMC ophthalmology · 2025

Comparative evaluation of several toric intraocular lens calculators for predicting postoperative refractive astigmatism in cataract surgery: a real-world study.

Xian Haocheng, Li Bingzhen, Xia Ziyao, Zhang Chun, Li Xuemin

СтатьяСравнительное исследованиеПеревод пока не подготовлен

Аннотация

BACKGROUND

This study aims to comprehensively evaluate the predictive accuracy of six widely used toric intraocular lens (IOL) calculators in eyes undergoing cataract surgery with toric IOL implantation.

METHODS

This retrospective study reviewed 53 eyes of 53 patients that underwent cataract extraction with toric IOL implantation using Zeiss 709 M. Six toric IOL calculators were evaluated: Barrett toric calculator (with predicted PCA, measured PCA, and TK), Kane formula (predicted PCA), and EVO 2.0 formula (predicted and measured PCA). Postoperative refractive astigmatism prediction errors were comprehensively calculated and analyzed using vector analysis.

RESULTS

The mean absolute prediction error (APE) ranged from 0.56 ± 0.37 D (Barrett TK) to 0.63 ± 0.46 D (Barrett predicted PCA, PPCA). The proportions of eyes achieving APE ≤ 1.0 D were highest for Barrett TK and Kane predicted PCA (90.6%). The highest proportions of eyes achieving APE ≤ 0.25 D and ≤ 0.50 D were observed with Barrett measured PCA (18.9% and 56.6%, respectively), while the lowest with Barrett PPCA (9.4% and 50.9%, respectively). The study found no statistically significant differences in mean absolute prediction error (APE) among the six calculators (χ² = 6.88, P = 0.23) and the centroid of PE (P = 0.93). A difference in mean APE was observed between the Barrett predicted PCA and Barrett TK calculators (P = 0.02).

CONCLUSION

The study confirms the importance of considering posterior corneal astigmatism remains essential to achieving precise refractive outcomes but also underscores the need for ongoing refinement and evaluation to optimize surgical outcomes.

Для цитирования: Xian Haocheng, Li Bingzhen, Xia Ziyao, Zhang Chun, Li Xuemin. Comparative evaluation of several toric intraocular lens calculators for predicting postoperative refractive astigmatism in cataract surgery: a real-world study.. BMC ophthalmology. 2025. DOI: 10.1186/s12886-025-03856-9.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.