MedElevator Войти в исследования
← Поиск публикаций

DOI 10.3928/1081597x-20241126-01

Медицинская библиотека · Journal of refractive surgery (Thorofare, N.J. : 1995) · 2025

A Nomogram to Improve the Predictability of High Myopic Astigmatism in Small Incision Lenticule Extraction Surgery.

Yu Na, Hou Xiangtao, Liu Chang, Chen Pei, Ye Yiming, Lan Min, Zhuang Jing, Yu Keming

СтатьяПеревод пока не подготовлен

Аннотация

PURPOSE: To evaluate a new regression-derived nomogram for high myopic astigmatism in small incision lenticule extraction (SMILE) surgery.

METHODS

In this prospective study, data from 180 eyes with myopic astigmatism ranging from -2.50 to -4.50 diopters (D) at 3 months after SMILE surgery were analyzed to construct the astigmatic nomogram. Linear regression between target induced astigmatism and flattening effect formula was derived as a nomogram to adjust astigmatic treatment. The nomogram was applied to 112 eyes with astigmatism ranging from -2.75 to -4.50 D. Subsequently, 143 eyes (manifest refraction group) with astigmatism greater than 2.50 D from 180 eyes were compared with 112 eyes (astigmatic nomogram group). Uncorrected distance visual acuity (UDVA), corrected distance visual acuity (CDVA), and refractive outcomes at 3 months postoperatively were recorded.

RESULTS

At 3 months after surgery, there was no difference in postoperative degree of astigmatism or UDVA between the two groups. In the astigmatic nomogram group, 109 (97%) of the eyes were within ±0.50 D compared with 127 (89%) in the manifest refraction group (P = .010). Target induced astigmatism and surgically induced astigmatism were strongly correlated in both groups. However, the average undercorrection in the manifest refraction group was 8.4% (R2 = 0.67), whereas the astigmatic nomogram group displayed 2.7% overcorrection (R2 = 0.86). Moreover, interestingly, all eyes in the astigmatic nomogram group had an angle of error within -5° to 5° compared with 137 (95.8%) of the eyes in the manifest refraction group (P = .028).

CONCLUSIONS

The astigmatic nomogram, based on regression between target induced astigmatism and flattening effect, could enhance the accuracy and predictability of high myopic astigmatism correction in SMILE surgery. [J Refract Surg. 2025;41(1):e65-e72.].

Для цитирования: Yu Na, Hou Xiangtao, Liu Chang, Chen Pei, Ye Yiming, Lan Min, Zhuang Jing, Yu Keming. A Nomogram to Improve the Predictability of High Myopic Astigmatism in Small Incision Lenticule Extraction Surgery.. Journal of refractive surgery (Thorofare, N.J. : 1995). 2025. DOI: 10.3928/1081597x-20241126-01.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.