MedElevator Войти в исследования
← Поиск публикаций

DOI 10.2147/opth.s485353

Медицинская библиотека · Clinical ophthalmology (Auckland, N.Z.) · 2024

Effect of Simple Myopic Astigmatism and Its Axis on Near Visual Performance for Thai Alphabet in Pseudophakic Eyes.

Pakviwat Pakpum, Moollaong Chureeporn, Borvonshivabhumi Sasinut, Roongpoovapatr Vatookarn

СтатьяПеревод пока не подготовлен

Аннотация

BACKGROUND

Refractive target of low simple myopic astigmatism allows increased depth-of-focus and near visual performance in monofocal intraocular lens (IOL) implants. This study investigated the effect of astigmatism and its axis on distance and near visual acuity (VA), and near visual performance for the Thai alphabet using the Thai MNREAD chart.

DESIGN

Investigational simulation.

METHODS

Distance (6.0 m) VA, near (40 cm) VA and near visual performance (maximum reading speed [MRS], threshold print size [TPS] and reading acuity [RA]), were assessed by the Thai MNREAD chart monocularly in 31 pseudophakic eyes (62.8 ± 8.55 years). Six refractive conditions were simulated using trial lenses: ±0.00 DS [in-focus at distance], +1.00 × 90 [ATR (Against-the-Rule)], +2.00 × 90 [ATR], +1.00 × 180 [WTR (With-the-Rule)], +2.00 × 180 [WTR], and +3.00 DS [in-focus at near].

RESULTS

Distance VA was degraded by spherical and astigmatic defocus compared with +0.00 DS [in-focus (distance)] (p < 0.001). No significant difference in distance VA was found between ATR and WTR astigmatism at the same magnitude. Near VA was better with +3.00 DS (p-value < 0.001) compared with other refractive conditions. Near visual performance (threshold print size [TPS]) was significantly better in ATR compared with WTR astigmatism (p <0.001 for both +1.00 DC and 2.00 DC).

CONCLUSION

Low simple myopic astigmatism improved near visual performance in monofocal IOL implants at the expense of degradation of distance VA. ATR astigmatism provided better TPS than WTR astigmatism. This benefit of ATR over WTR astigmatism on reading performance on the Thai alphabet confirmed the role of axis orientation on near visual performance.

Для цитирования: Pakviwat Pakpum, Moollaong Chureeporn, Borvonshivabhumi Sasinut, Roongpoovapatr Vatookarn. Effect of Simple Myopic Astigmatism and Its Axis on Near Visual Performance for Thai Alphabet in Pseudophakic Eyes.. Clinical ophthalmology (Auckland, N.Z.). 2024. DOI: 10.2147/opth.s485353.
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.