MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.jviromet.2018.02.012

Медицинская библиотека · Journal of virological methods · 2018

A multiplexed RT-LAMP assay for detection of group M HIV-1 in plasma or whole blood.

Curtis Kelly A, Morrison Daphne, Rudolph Donna L, Shankar Anupama, Bloomfield Laura S P, Switzer William M, Owen S Michele

СтатьяПоддержка NIH: внешняя программаПоддержка службы здравоохранения СШАПеревод в очереди

Аннотация

Isothermal nucleic acid amplification techniques, such as reverse-transcription loop-mediated isothermal amplification (RT-LAMP), exhibit characteristics that are suitable for the development of a rapid, low-cost NAT that can be used at the POC. For demonstration of utility for global use, studies are needed to validate the performance of RT-LAMP for the detection of divergent subtypes. In this study, we designed and evaluated multiplexed HIV-1 integrase RT-LAMP primers to detect subtypes within group M, along with an RNase P positive internal processing and amplification control. Using a panel of 26 viral isolates representing the major circulating subtypes, we demonstrated detection of all isolates of subtypes A1, C, D, F1, F2, G, CRF01_AE, CRF02_AG, and two unique recombinant forms (URFs). A whole blood panel created with one representative isolate of each subtype was successfully amplified with the group M HIV-1 integrase and RNase P internal control primers. The group M HIV-1 RT-LAMP assay was further evaluated on 61 plasma specimens obtained from persons from Cameroon and Uganda. The sequence-conserved group M HIV-1 RT-LAMP primers, coupled to a low-cost amplification device, may improve diagnosis of acute infection at the POC and provide timely confirmation of HIV status.

Для цитирования: Curtis Kelly A, Morrison Daphne, Rudolph Donna L, Shankar Anupama, Bloomfield Laura S P, Switzer William M, Owen S Michele. A multiplexed RT-LAMP assay for detection of group M HIV-1 in plasma or whole blood.. Journal of virological methods. 2018. DOI: 10.1016/j.jviromet.2018.02.012.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.