m+Medelevator.RU
← Поиск публикаций
Open veterinary journal · 2026

A 12-lead or 10-lead electrocardiogram in cats? An analysis comparing 6-lead and 4-lead precordial systems.

СтатьяСравнительное исследованиеНазвание и аннотация: Перевод пока не подготовлен
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Nascimento Laura Gonçalves, Coelho Mariana de Resende, Ribeiro Diego, Resende Isa Lúcia Sousa, Kawamoto Fernando Yoiti Kitamura, de Oliveira Luiz Eduardo Duarte, Lima Jullia de Almeida, de Abreu Claudine Botelho

Аннотация

BACKGROUND: Electrocardiography is widely used in feline cardiology, but precordial lead placement remains poorly standardized for this species. Although six-lead precordial systems have been validated in dogs, their applicability to cats remains uncertain. This is due to the species' distinct thoracic conformation and the potential stress associated with electrode placement. A simplified precordial arrangement may improve patient comfort, but its diagnostic equivalence has not been fully investigated.

AIM: To compare six (6P) and four (4P) precordial lead systems in feline electrocardiography and evaluate their clinical applicability, impact on wave measurements, and patient tolerance.

METHODS: Forty healthy, non-sedated adult cats were included. All animals underwent two electrocardiographic examinations in right lateral recumbency. The 6P system was applied as standardized in dogs. The 4P system consisted of one electrode positioned in the first right intercostal space and three electrodes spaced proportionally in the sixth left intercostal space. Amplitudes and durations of P, R, S, and T waves were recorded and compared within and between systems. Associations with demographic variables were assessed. Observational assessment of patient tolerance was conducted during both examinations.

RESULTS: Wave morphology varied slightly between systems. R-wave amplitude was consistently higher in the 6P system and showed a progressive decrease from V2 toward caudodorsal leads. The 4P system produced slightly longer P-wave durations. In contrast, R-, S-, and T-wave amplitudes tended to be higher in the 6P recordings. No significant associations were identified between electrocardiographic measurements and age, sex, or body weight. Cats demonstrated visibly greater tolerance to the 4P system, with fewer attempts to reposition or resist handling.

CONCLUSION: Both the 6P and 4P precordial lead systems provide reliable electrocardiographic tracings in cats and can be used in clinical practice. However, the improved patient tolerance observed with the 4P arrangement suggests that it may be preferable in routine examinations. This approach maintains diagnostic usefulness while enhancing feline comfort.

Предметные рубрики MeSH

ИП Урсолов Владлен Сергеевич

ИНН 500118482352 · ОГРНИП 314500117700049

Реквизиты и контакты