MedElevator Войти в исследования
← Поиск публикаций

DOI 10.5603/cj.a2021.0093

Медицинская библиотека · Cardiology journal · 2021

Transfermoral transcatheter aortic valve implantation using self-expanding Allegra bioprosthesis: One-year single-center outcomes.

Milan Joanna, Gozdek Mirosław, Targoński Radosław, Kowalewski Mariusz, Stańska Aleksandra, Fijałkowski Marcin, Lango Romuald, Jaguszewski Miłosz, Jagielak Dariusz

СтатьяНаблюдательное исследованиеПеревод пока не подготовлен

Аннотация

BACKGROUND

The NAUTILUS study aimed to evaluate the safety and performance of the Allegra bioprosthesis in high-risk recipients undergoing transcatheter aortic valve implantation and previously reported 30-day outcomes. In the current investigation 1-year results of the trial are presented.

METHODS

Twenty-seven recipients with severe, symptomatic aortic valve stenosis at high surgical risk, who underwent treatment using the next-generation self-expanding Allegra via transfemoral approach were prospectively enrolled. Clinical endpoints assessed were: mortality, stroke, permanent pacemaker implantation, New York Heart Association class and re-hospitalizations. Prosthetic valve performance evaluation comprised of: mean gradient, effective orifice area and paravalvular leak.

RESULTS

Patients were elderly (82.8 ± 4.2 years) and predominantly female (n = 19, 70.4%). All of them were deemed to be at high surgical risk with a mean logistic EuroSCORE of 12.5 ± 6.7. The bioprosthesis was successfully implanted in 92.6% of the cases (n = 25). At 1-year, all-cause mortality was 12.0% (n = 3) and stroke was 4.0% (n = 1). Three (12%) of patients developed complete atrioventricular block and received permanent pacemakers. 84% of patients were in New York Heart Association class II or lower. Need for subsequent hospitalization arose in 48% patients. The echocardiographic assessment confirmed an acceptable hemodynamic profile of the Allegra with low mean transprosthetic gradient (9.5 ± 3.4 mmHg), absence of severe paravalvular leak and a 20%-presence of moderate paravalvular leak.

CONCLUSIONS

The current follow-up observation study shows that the Allegra was associated with a satisfactory safety profile and hemodynamic performance at 1-year after implantation.

Для цитирования: Milan Joanna, Gozdek Mirosław, Targoński Radosław, Kowalewski Mariusz, Stańska Aleksandra, Fijałkowski Marcin, Lango Romuald, Jaguszewski Miłosz, Jagielak Dariusz. Transfermoral transcatheter aortic valve implantation using self-expanding Allegra bioprosthesis: One-year single-center outcomes.. Cardiology journal. 2021. DOI: 10.5603/cj.a2021.0093.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.