MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1536/ihj.20-120

Медицинская библиотека · International heart journal · 2020

Evolut Self-Expanding Transcatheter Aortic Valve Replacement in Patients with Extremely Horizontal Aorta (Aortic Root Angle ≥ 70°).

Kaneko Umihiko, Hachinohe Daisuke, Kobayashi Ken, Shitan Hidemasa, Mitsube Keijiro, Furugen Azusa, Kawamura Takeshi, Koshima Ryuji, Fujita Tsutomu

СтатьяПеревод пока не подготовлен

Аннотация

Because of its rigidity and non-steerability, the presence of a horizontal aortic root poses a major anatomical issue during transcatheter aortic valve replacement (TAVR) with Evolut self-expanding valve. Previous studies have elucidated the difficulties of coaxial implantation of the self-expanding valve in patients with horizontal aorta, often resulting in increased complications and a lower device success rate. To date, most patients with extremely horizontal aorta (aortic root angle ≥ 70°) have been excluded from major TAVR clinical trials. Therefore, available data on TAVR with Evolut in this challenging anatomy are limited, and standardized treatment strategies and clinical results remain unknown. Herein, we report a clinical case series of TAVR with Evolut in extremely horizontal aorta. Among seven patients (aged 80-92 years; STS score, 12.6% ± 7.9%) who underwent TAVR with Evolut system, aortic root angle ranged from 71° to 83° (mean, 75.1°± 4.5°). All patients achieved device success with dedicated strategies and were clinically stable at 3-month follow-up. None of the patients had more than mild paravalvular leakage (PVL) at any point during follow-up.Complications in three patients included complete atrioventricular block requiring a permanent pacemaker implantation, cerebral infarction because of atrial fibrillation 3 days after TAVR, and cardiac tamponade requiring pericardiocentesis. In this case series, Evolut self-expanding TAVR in extremely horizontal aorta was effective and feasible with a high device success rate. Based on anatomical features, some dedicated strategies majorly contribute to the success of this procedure. Large-scale multicenter studies are required to confirm our findings.

Для цитирования: Kaneko Umihiko, Hachinohe Daisuke, Kobayashi Ken, Shitan Hidemasa, Mitsube Keijiro, Furugen Azusa, Kawamura Takeshi, Koshima Ryuji, Fujita Tsutomu. Evolut Self-Expanding Transcatheter Aortic Valve Replacement in Patients with Extremely Horizontal Aorta (Aortic Root Angle ≥ 70°).. International heart journal. 2020. DOI: 10.1536/ihj.20-120.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.