MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1002/ccd.29227

Медицинская библиотека · Catheterization and cardiovascular interventions : official journal of the Society for Cardiac Angiography & Interventions · 2020

Prevalence, predictors, and outcomes of patient prosthesis mismatch in women undergoing TAVI for severe aortic stenosis: Insights from the WIN-TAVI registry.

Panoulas Vasileios F, Chandrasekhar Jaya, Busi Gherardo, Ruparelia Neil, Zhang Zhongjie, Mehilli Julinda, Sartori Samantha, Lefèvre Thierre, Presbitero Patrizia, Capranzano Piera, Tchetche Didier, Iadanza Alessandro, Sardella Gennaro, Van Mieghem Nicolas M, Meliga Emanuele, Dumonteil Nicolas, Fraccaro Chiara, Trabattoni Daniela, Sharma Samin, Ferrer-Gracia Maria-Cruz, Naber Christoph K, Kievit Peter C, Snyder Clayton, Sutaria Nilesh, Sen Sayan, Malik Iqbal S, Morice Marie-Claude, Nihoyannopoulos Petros, Petronio Anna Sonia, Mehran Roxana, Chieffo Alaide, Mikhail Ghada W, WIN-TAVI Investigators

СтатьяМногоцентровое исследованиеПеревод пока не подготовлен

Аннотация

OBJECTIVE

To evaluate the incidence, predictors and outcomes of female patients with patient-prosthesis mismatch (PPM) following transcatheter aortic valve intervention (TAVI) for severe aortic stenosis (AS).

BACKGROUND

Female AS TAVI recipients have a significantly lower mortality than surgical aortic valve replacement (SAVR) recipients, which could be attributed to the potentially lower PPM rates. TAVI has been associated with lower rates of PPM compared to SAVR. PPM in females post TAVI has not been investigated to date.

METHODS

The WIN-TAVI (Women's INternational Transcatheter Aortic Valve Implantation) registry is a multicenter registry of women undergoing TAVR for severe symptomatic AS. Two hundred and fifty patients with detailed periprocedural and follow-up echocardiographic investigations were included in the WIN-TAVI echocardiographic sub-study. PPM was defined as per European guidelines stratified by the presence of obesity.

RESULTS

The incidence of PPM in our population was 32.8%. Patients with PPM had significantly higher BMI (27.4 ± 6.1 vs. 25.2 ± 5.0, p = .002), smaller sized valves implanted (percentage of TAVI ≤23 mm 61% vs. 29.2%, PPM vs. no PPM, p < .001) and were more often treated with balloon expandable valves (48.3 vs. 32.5%, p < .001) rather than self expanding ones (26.3 vs. 52.8%, <.001). BMI (OR = 1.08; 95%CI 1.02-1.14, p = .011) and valve size ≤23 mm (OR = 3.00 95%CI 1.14-7.94, p = .027) were the only independent predictors of PPM. There was no significant interaction between valve size and valve type (p = .203). No significant differences were observed in 1-year mortality or major adverse cardiovascular events.

CONCLUSIONS

PPM in females undergoing TAVI occurs in one third of patients. BMI and valve size ≤23 mm are independent predictors. Larger registries are required to determine the impact of PPM on future clinical outcomes.

Для цитирования: Panoulas Vasileios F, Chandrasekhar Jaya, Busi Gherardo, Ruparelia Neil, Zhang Zhongjie, Mehilli Julinda, Sartori Samantha, Lefèvre Thierre, Presbitero Patrizia, Capranzano Piera, Tchetche Didier, Iadanza Alessandro, Sardella Gennaro, Van Mieghem Nicolas M, Meliga Emanuele, Dumonteil Nicolas, Fraccaro Chiara, Trabattoni Daniela, Sharma Samin, Ferrer-Gracia Maria-Cruz, Naber Christoph K, Kievit Peter C, Snyder Clayton, Sutaria Nilesh, Sen Sayan, Malik Iqbal S, Morice Marie-Claude, Nihoyannopoulos Petros, Petronio Anna Sonia, Mehran Roxana, Chieffo Alaide, Mikhail Ghada W, WIN-TAVI Investigators. Prevalence, predictors, and outcomes of patient prosthesis mismatch in women undergoing TAVI for severe aortic stenosis: Insights from the WIN-TAVI registry.. Catheterization and cardiovascular interventions : official journal of the Society for Cardiac Angiography & Interventions. 2020. DOI: 10.1002/ccd.29227.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.