MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.jcmg.2020.04.011

Медицинская библиотека · JACC. Cardiovascular imaging · 2020

Comparison Between ESC and Duke Criteria for the Diagnosis of Prosthetic Valve Infective Endocarditis.

Philip Mary, Tessonier Laetitia, Mancini Julien, Mainardi Jean-Luc, Fernandez-Gerlinger Marie-Paule, Lussato David, Attias David, Cammilleri Serge, Weinmann Pierre, Hagege Albert, Arregle Florent, Martel Hélène, Oliver Leopold, Camoin Laurence, Casalta Anne Claire, Casalta Jean Paul, Gouriet Frédérique, Riberi Alberto, Lepidi Hubert, Raoult Didier, Drancourt Michel, Habib Gilbert

СтатьяПоддержка исследования: вне правительства СШАПеревод пока не подготовлен

Аннотация

OBJECTIVES

The primary objective was to assess the value of the European Society of Cardiology (ESC) criteria, including 18F-fluorodeoxyglucose positron emission tomography/computed tomography (18F-FDG-PET/CT) in prosthetic valve infective endocarditis (PVE). Secondary objectives were: 1) to assess the reproducibility of 18F-FDG-PET/CT; 2) to compare its diagnostic value with that of echocardiography; and 3) to assess the diagnostic value of the presence of a diffuse splenic uptake

BACKGROUND

18F-FDG PET/CT has been added as a major criterion in the ESC 2015 infective endocarditis (IE) guidelines, but the benefit of the ESC criteria has not been prospectively compared with the conventional Duke criteria.

METHODS

Between 2014 and 2017, 175 patients with suspected PVE were prospectively included in 3 French centers. After exclusion of patients with uninterpretable 18F-FDG PET/CT, 115 patients were evaluated, including 91 definite and 24 rejected IE, as defined by an expert consensus.

RESULTS

Cardiac uptake by 18F-FDG PET/CT was observed in 67 of 91 patients with definite PVE and 6 with rejected IE (sensitivity 73.6% [95% confidence interval (CI): 63.3% to 82.3%], specificity 75% [95% CI: 53.3% to 90.2%]). The ESC 2015 classification increased the sensitivity of Duke criteria from 57.1% (95% CI: 46.3% to 67.5%) to 83.5% (95% CI: 74.3% to 90.5%) (p < 0.001), but decreased its specificity from 95.8% (95% CI: 78.9% to 99.9%) to 70.8% (95% CI: 48.9% to 87.4%). Intraobserver reproducibility of 18F-FDG PET/CT was good (kappa = 0.84) but interobserver reproducibility was less satisfactory (kappa = 0.63). A diffuse splenic uptake was observed in 24 (20.3%) patients, including 23 (25.3%) of definite PVE, and only 1 (4.2%) rejected PVE (p = 0.024).

CONCLUSIONS

18F-FDG PET/CT is a useful diagnostic tool in suspected PVE, and explains the greater sensitivity of ESC criteria than Duke criteria. However, 18F-FDG PET/CT also presents with important limitations concerning its feasibility, specificity, and reproducibility. Our study describes for the first time a new endocarditis criterion, that is, the presence of a diffuse splenic uptake on 18F-FDG PET/CT.

Для цитирования: Philip Mary, Tessonier Laetitia, Mancini Julien, Mainardi Jean-Luc, Fernandez-Gerlinger Marie-Paule, Lussato David, Attias David, Cammilleri Serge, Weinmann Pierre, Hagege Albert, Arregle Florent, Martel Hélène, Oliver Leopold, Camoin Laurence, Casalta Anne Claire, Casalta Jean Paul, Gouriet Frédérique, Riberi Alberto, Lepidi Hubert, Raoult Didier, Drancourt Michel, Habib Gilbert. Comparison Between ESC and Duke Criteria for the Diagnosis of Prosthetic Valve Infective Endocarditis.. JACC. Cardiovascular imaging. 2020. DOI: 10.1016/j.jcmg.2020.04.011.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.