MedElevator Войти в исследования
← Поиск публикаций

DOI 10.12998/wjcc.v7.i21.3549

Медицинская библиотека · World journal of clinical cases · 2019

Transfemoral aortic valve implantation in the case of pre-existing mitral prosthesis and pure aortic regurgitation: A case report.

Erdem Aysun, Esen Zencirci Aycan, Ozden Kivilcim, Terzi Sait

Клинический случайСтатьяПеревод пока не подготовлен

Аннотация

BACKGROUND

Transcatheter aortic valve replacement (TAVR) is recommended in patients with severe aortic stenosis who have high surgical risk. However, in the pre-existing mechanical mitral valve prosthesis and natural pure aortic regurgitation, TAVR is relatively contraindicated. In this report, we described one case of TAVR with native aortic regurgitation in the presence of mechanical mitral valve prosthesis.

CASE SUMMARY: A 64-year-old man with a medical history of mitral valve replacement had severe dyspnea and was symptomatic even at rest for 3 mo. His echocardiography showed severe native pure aortic regurgitation. His euroscore was 15. A TAVR procedure with an evolut R was planned. A 34 mm evolut R was placed by transesophageal echocardiography. The mitral prosthesis was functioning normally, and mild-moderate paravalvular leakage was evident by transesophageal echocardiography. The patient recovered without any complication. At 1 mo follow up, the patient was well, and no paravalvular leakage was noted.

CONCLUSION

TAVR for pure aortic regurgitation in the presence of prosthetic mitral valve can be a safe procedure.

Для цитирования: Erdem Aysun, Esen Zencirci Aycan, Ozden Kivilcim, Terzi Sait. Transfemoral aortic valve implantation in the case of pre-existing mitral prosthesis and pure aortic regurgitation: A case report.. World journal of clinical cases. 2019. DOI: 10.12998/wjcc.v7.i21.3549.
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.