MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1002/ccd.27927

Медицинская библиотека · Catheterization and cardiovascular interventions : official journal of the Society for Cardiac Angiography & Interventions · 2018

Hemodynamic durability of transcatheter aortic valves using the updated Valve Academic Research Consortium-2 criteria.

Kumar Arnav, Sato Kimi, Banerjee Kinjal, Narayanswami Jyoti, Betancor Jorge, Menon Vivek, Mohananey Divyanshu, Anumandla Anil Kumar, Sawant Abhishek C, Krishnaswamy Amar, Tuzcu E Murat, Jaber Wael, Mick Stephanie, Svensson Lars G, Popović Zoran B, Blackstone Eugene H, Kapadia Samir R

СтатьяНаблюдательное исследованиеПеревод пока не подготовлен

Аннотация

OBJECTIVES

We investigated the hemodynamic durability of the transcatheter aortic valves (TAVs) using the updated Valve Academic Research Consortium-2 (VARC-2) criteria.

BACKGROUND

The updated VARC-2 consensus criteria combine flow-dependent and flow-independent echocardiographic parameters for hemodynamic assessment of TAVR. Data on the hemodynamic durability of TAV and clinical risk factors associated with valve hemodynamic deterioration (VHD) are lacking.

METHODS

All patients (n = 276) who received TAV between 2006 and 2012 and had ≥2 follow-up echocardiograms were studied.

RESULTS

During a median follow up period of 3.3 (1.8-4.4) years, 8 patients (3%) developed moderate to severe valve stenosis per the VARC-2 criteria, while 20 had mild stenosis. In a Cox proportional hazards model analysis, moderate to severe stenosis by VARC-2 criteria was associated with younger age (P = 0.03, HR 0.94), absence of dual antiplatelet therapy (DAPT) (P = 0.026, HR 0.18), and lower baseline left ventricular ejection fraction (LVEF) (P = 0.006, HR 0.94). Longitudinal analysis using a mixed effect model showed that presence of stenosis by VARC-2 criteria was associated with an increase in aortic valve mean gradient (P < 0.001, +2.34 mmHg per year). In a subset of 93 patients with analyzable fluoroscopic images, deeper valve implantation was associated with increase in mean gradient (P = 0.004, +0.2 mmHg per year per 1 mm increase in implantation depth).

CONCLUSION

Despite good hemodynamic durability of TAV, patients with younger age, lower LVEF and those not on DAPT after undergoing a TAV replacement, are at a higher risk for development of VHD.

Для цитирования: Kumar Arnav, Sato Kimi, Banerjee Kinjal, Narayanswami Jyoti, Betancor Jorge, Menon Vivek, Mohananey Divyanshu, Anumandla Anil Kumar, Sawant Abhishek C, Krishnaswamy Amar, Tuzcu E Murat, Jaber Wael, Mick Stephanie, Svensson Lars G, Popović Zoran B, Blackstone Eugene H, Kapadia Samir R. Hemodynamic durability of transcatheter aortic valves using the updated Valve Academic Research Consortium-2 criteria.. Catheterization and cardiovascular interventions : official journal of the Society for Cardiac Angiography & Interventions. 2018. DOI: 10.1002/ccd.27927.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.