MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1002/jbm.b.10061

Медицинская библиотека · Journal of biomedical materials research. Part B, Applied biomaterials · 2003

Polydimethylsiloxane versus polytetrafluoroethylene for vocal fold medialization: histologic evaluation in a rabbit model.

Caballero Miguel, Bernal-Sprekelsen Manuel, Calvo Carlos, Farrè Xavier, Quintó Lorenc, Alòs Lucia

Сравнительное исследованиеОценочное исследованиеСтатьяПоддержка исследования: вне правительства СШАПеревод пока не подготовлен

Аннотация

The objective is to study the tissue reaction of the paralyzed vocal cord in response to the injection of particulate plastics in a rabbit model. Forty-five New Zealand rabbits with surgical vocal-fold paralysis were used in the study. Histologic reactions of the larynx and the regional lymph nodes were analyzed by a single blinded pathologist at 6 weeks and 6 months after a vocal-cord injection of Teflon or of silicone elastomer. Macroscopic studies of the liver, lungs, spleen, kidney, and brain were performed. The histological study showed a greater proportion of chronic granulomatous inflammation in animals injected with silicone than in those injected with Teflon. The immunohistochemical study showed a higher degree of phagocytosis of Teflon particles than of the silicone particles. The silicone group presented a more severe fibrous reaction than the Teflon group, but the difference was not significant. No migration particles were found. It is concluded that silicone, having a greater viscosity than Teflon because of the size of its particles, induces more fibrosis and a larger proportion of foreign giant cells in the host. Due to this histological reaction, silicone particles present greater anchorage and stability.

Для цитирования: Caballero Miguel, Bernal-Sprekelsen Manuel, Calvo Carlos, Farrè Xavier, Quintó Lorenc, Alòs Lucia. Polydimethylsiloxane versus polytetrafluoroethylene for vocal fold medialization: histologic evaluation in a rabbit model.. Journal of biomedical materials research. Part B, Applied biomaterials. 2003. DOI: 10.1002/jbm.b.10061.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.