MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1055/a-2786-2534

Медицинская библиотека · RoFo : Fortschritte auf dem Gebiete der Rontgenstrahlen und der Nuklearmedizin · 2026

Inter- and intra-individual radiation dose variability in oncologic chest and abdominal computed tomography.

Moradians Arian Felix, Rosok Daniel, Serger Raya, Klüner Laura Valentina, Drews Marcel, Behr Florian, Salhöfer Luca, Bos Denise, Forsting Michael, Haubold Johannes, Opitz Marcel Klaus, Zensen Sebastian

СтатьяПеревод пока не подготовлен

Аннотация

PURPOSE: Computed tomography (CT) plays a central role in oncologic imaging, yet repeated examinations contribute substantially to cumulative radiation exposure. This study aimed to evaluate inter- and intra-individual radiation dose variability in chest and abdominal CT and the impact of CT device model and protocol standardization.

MATERIALS AND

METHODS

In this retrospective single-center study, 42441 CT scans from 4986 adult oncologic patients were analyzed. Dose metrics (CTDIvol, DLP, SSDE, effective dose) were extracted using automated dose monitoring. Inter- and intra-individual radiation dose variability was assessed across four CT device models and various protocol subtypes. Intra-individual radiation dose variability was calculated relative to the lowest dose per patient and compared across CT devices and protocol subtypes.

RESULTS

Radiation dose varied substantially between devices, with CTDIvol differences of up to 2.4-fold in chest CT (2.98-7.26 mGy) and 1.7-fold in abdominal CT (5.26-8.77 mGy). The median intra-individual radiation dose variability was 93.7% (IQR 19.8-142.0%) in non-contrast chest CT, 66.3% (31.1-105.4%) in contrast-enhanced chest CT, 19.8% (11.8-32.3%) in non-contrast abdominal CT, and 28.2% (16.6-41.0%) in contrast-enhanced abdominal CT. When consecutive scans were performed on the same scanner, intra-individual radiation dose variability decreased to 14.7% (IQR 8.1-33.1%), 18.1% (9.5-31.3%), 11.7% (7.8-19.8%), and 15.3% (8.3-24.7%), respectively, indicating substantial device-specific effects.

CONCLUSION

Significant radiation dose variability persists in oncologic CT, both between and within patients, despite the use of standardized protocols. Device-adapted dose management and consistent device use may improve dose consistency, support optimization in oncologic imaging, and reduce radiation exposure.

KEY POINTS: · Substantial radiation dose variability persists across CT devices despite protocol standardization.. · Intra-individual radiation dose variability is significant and highest in non-contrast chest CT.. · Consistent use of the same scanner reduces intra-individual radiation dose variability significantly.. · Internal diagnostic reference levels may improve radiation dose consistency and minimize exposure..

CITATION FORMAT: · Moradians AF, Rosok D, Serger R et al. Inter- and intra-individual radiation dose variability in oncologic chest and abdominal computed tomography. Rofo 2026; DOI 10.1055/a-2786-2534.

Для цитирования: Moradians Arian Felix, Rosok Daniel, Serger Raya, Klüner Laura Valentina, Drews Marcel, Behr Florian, Salhöfer Luca, Bos Denise, Forsting Michael, Haubold Johannes, Opitz Marcel Klaus, Zensen Sebastian. Inter- and intra-individual radiation dose variability in oncologic chest and abdominal computed tomography.. RoFo : Fortschritte auf dem Gebiete der Rontgenstrahlen und der Nuklearmedizin. 2026. DOI: 10.1055/a-2786-2534.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.