MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/0002-9149(85)91134-8

Медицинская библиотека · The American journal of cardiology · 1985

Value of intraoperative left ventricular microbubbles detected by transesophageal two-dimensional echocardiography in predicting neurologic outcome after cardiac operations.

Topol E J, Humphrey L S, Borkon A M, Baumgartner W A, Dorsey D L, Reitz B A, Weiss J L

СтатьяПоддержка исследования: вне правительства СШАПоддержка службы здравоохранения СШАПеревод пока не подготовлен

Аннотация

To determine whether the presence or absence of left ventricular (LV) intracavitary microbubbles during cardiac surgery predicts neurologic sequelae, 82 patients undergoing cardiac surgery were studied using transesophageal 2-dimensional (2-D) echocardiography. Cross-sectional images were recorded just before and immediately after cardiopulmonary bypass and stop frames were reviewed for the presence of microbubbles, rated as: 0 = absent, 1 = fewer than 5/frame, 2 = 10 to 25/frame, 3 = too numerous to count. Microbubbles were detected after cardiopulmonary bypass in 34 patients (41%) and found more often in valvular or other intracardiac manipulations than in coronary revascularization, 30 of 40 vs 4 of 42, respectively (p less than 0.001). When grade 2 or 3 microbubbles were identified (22 of 34 patients), mechanical attempts to eradicate them were not successful. Postoperative follow-up in all patients revealed no new focal neurologic deficits. Prolonged encephalopathy (confusional state more than 72 hours) occurred in 4 of 48 patients with no detectable microbubbles and in 3 of 34 patients with microbubbles (difference not significant). Thus, intracavitary left ventricular microbubbles are often detected during cardiac operations, particularly during valve replacement, but are not predictive of postoperative neurologic complications. This is true even if microbubbles are densely concentrated; attempts to eradicate microbubbles are unsuccessful and may be unnecessary.

Для цитирования: Topol E J, Humphrey L S, Borkon A M, Baumgartner W A, Dorsey D L, Reitz B A, Weiss J L. Value of intraoperative left ventricular microbubbles detected by transesophageal two-dimensional echocardiography in predicting neurologic outcome after cardiac operations.. The American journal of cardiology. 1985. DOI: 10.1016/0002-9149(85)91134-8.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.