MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1002/jbio.201800259

Медицинская библиотека · Journal of biophotonics · 2018

Patient-specific determination of change in ocular spherical aberration to improve near and intermediate visual acuity of presbyopic eyes.

Shetty Naren, Kochar Shruti, Paritekar Prajakta, Artal Pablo, Shetty Rohit, Nuijts Rudy M M A, Webers Carroll A B, Sinha Roy Abhijit

СтатьяПеревод пока не подготовлен

Аннотация

The purpose was to determine the optimum negative spherical aberration induction required to improve near and intermediate visual acuity (VA) of presbyopic eyes. A total of 174 normal and diabetic (no retinopathy) presbyopic eyes (age ≥ 40 years) were measured with visual adaptive optics simulator (Voptica, Spain). First, baseline uncorrected VA and aberrations were measured. VA at 40 cm (near), 80 cm (intermediate) and distance was measured. Then, a negative spherical aberration (SA) was added to baseline ocular SA, and VA at all targets was reassessed after correction of distance refractive error. Clinically, baseline SA and root mean square of higher order aberrations were similar between the normal and diabetic presbyopic eyes. Baseline VA of the diabetic eyes at near and intermediate was better than the same of normal eyes (P = 0.001). After SA change, VA at near and intermediate of both normal and diabetic presbyopic eyes improved. However, fewer diabetic eyes needed higher SA change than normal eyes (P = 0.03). The corresponding trends with change in VA at near and intermediate were also similar between the normal and diabetic eyes. Patient-specific modulation of ocular SA to improve near and intermediate VA in a large cohort of eyes was successful in improving VA, sometimes even distance VA.

Для цитирования: Shetty Naren, Kochar Shruti, Paritekar Prajakta, Artal Pablo, Shetty Rohit, Nuijts Rudy M M A, Webers Carroll A B, Sinha Roy Abhijit. Patient-specific determination of change in ocular spherical aberration to improve near and intermediate visual acuity of presbyopic eyes.. Journal of biophotonics. 2018. DOI: 10.1002/jbio.201800259.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.