DOI 10.2174/1874364101812010273
Maximising Refractive Outcomes with an Extended Depth of Focus IOL.
Аннотация
OBJECTIVE
To assess the impact of the magnitude of preoperative and postoperative corneal astigmatism on refractive outcomes in patients undergoing cataract surgery or lens exchange with an extended depth of focus intraocular lens. To compare visual outcomes of steep and temporal on-axis corneal incisions.
SETTING
Department of Ophthalmology, Blackrock Clinic, Dublin, Ireland.
DESIGN
Prospective cohort analysis.
METHODS
Fifty-three consecutive adult patients (94 eyes) undergoing routine phacoemulsification with Symfony IOL implantation were analysed. Exclusion criteria: targets for mini-monovision, incomplete data, other ocular pathology. Data were prospectively collected on pre- and postoperative refraction, keratometry, distance vision, near vision, surgical wound site and Surgically Induced Astigmatism (SIA).
RESULTS
The average postoperative monocular Uncorrected Distance and Near visual acuities (UDVA and UNVA) were 0.12 LogMAR (± 0.1) (6/7.5+1) and 0.34 LogMAR (± 0.09) respectively. The average binocular UDVA and UNVA were 0.05 (± 0.07) and 0.29 LogMAR (± 0.06) respectively. Low levels of preoperative corneal astigmatism (0-0.99 D) were associated with better LogMAR UDVA and UNVA when compared with higher levels (> 0.99 D): 0.11 (CI 0.103-0.107) vs. 0.206 (CI 0.122-0.290) (p =0.015, CI 95%) and 0.33 (CI 0.316 - 0.356) vs. 0.39 (CI 0.34-0.43) (p =0.034, CI 95%) respectively. When patients with steep on-axis corneal incisions were compared with temporal on-axis corneal incisions, no difference was detected in visual outcome or SIA.
CONCLUSION
The Symfony IOL is an effective surgical means of addressing presbyopia and reducing postoperative spectacle dependence. We stress caution when offering potential spectacle independence for patients with over 1D of preoperative corneal astigmatism as these patients achieve statistically significantly inferior and less predictable visual results.