MedElevator Войти в исследования
← Поиск публикаций

DOI 10.2147/opth.s164964

Медицинская библиотека · Clinical ophthalmology (Auckland, N.Z.) · 2018

Long-term changes in keratometry and refraction after small aperture corneal inlay implantation.

Moshirfar Majid, Desautels Jordan D, Walker Brian D, Birdsong Orry C, Skanchy David F, Quist Tyler S, Murri Michael S, Linn Steve H, Hoopes Phillip C, Hoopes Phillip C

СтатьяПеревод пока не подготовлен

Аннотация

PURPOSE: To assess longitudinal refractive, keratometric, and topographic changes following KAMRA small-aperture inlay implantation.

DESIGN AND

SETTING

Prospective study at a single site refractive surgery center.

METHODS

Fifty patients underwent KAMRA small-aperture corneal inlay implantation for the correction of presbyopia. Uncorrected near visual acuity (UNVA), uncorrected distance visual acuity, manifest refractive spherical equivalent (MRSE), mean keratometry (Km), corneal topography, and surgically induced astigmatism vector analysis assessments were performed preoperatively and at 1, 3, 6, 12, 24, and 36 months postoperatively.

RESULTS

The study comprises 50 eyes. An average shift of 0.15±0.63 D (range -1.63 to 2.00 D) occurred between preoperative baseline and 36 months. At 36 months, 54% of patients had hyperopic MRSE and 40% had myopic MRSE compared with baseline. Km was significantly elevated at all postoperative measurements compared with baseline, with the largest Km measured at 12 months. Eighty-six percent of patients had UNVA of 20/32 or better and 88% uncorrected distance visual acuity of 20/25 or better at 36 months. Longitudinal corneal topography revealed a pattern of corneal steepening over the body of the inlay and flattening over the aperture, correlating with a hyperopic shift. There was no significant surgically induced astigmatism.

CONCLUSION

KAMRA inlay may cause an increase in Km compared with baseline. Corneal steepening may occur in a specific pattern with steepening over the inlay and flattening over the aperture. This topographic pattern causes a hyperopic shift, which may be relevant for subsequent procedures, such as cataract extraction.

Для цитирования: Moshirfar Majid, Desautels Jordan D, Walker Brian D, Birdsong Orry C, Skanchy David F, Quist Tyler S, Murri Michael S, Linn Steve H, Hoopes Phillip C, Hoopes Phillip C. Long-term changes in keratometry and refraction after small aperture corneal inlay implantation.. Clinical ophthalmology (Auckland, N.Z.). 2018. DOI: 10.2147/opth.s164964.
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.