Comparison of the influence of corneo-scleral and scleral lenses on ocular surface and tear film metrics in a presbyopic population.

Lafosse Edouard, Romín Daniel Monsálvez, Esteve-Taboada José-Juan, Wolffsohn James S, Talens-Estarelles Cristian, García-Lázaro Santiago

СтатьяПеревод пока не подготовлен

Аннотация

PURPOSE: To assess and compare the effect of the corneo-scleral lenses (C-ScL) and scleral lenses (ScL) on tear film parameters and central corneal thickness (CCT) in healthy presbyopic subjects.

METHODS

Thirty subjects wore two contact lenses (CLs), randomly assigned, of neutral power, but of different diameters, 12.7mm (C-ScL) and 18mm (ScL) and being equal in the others parameters: material (HS100) and centre thickness (0.29mm). At baseline, 20min after insertion and at 8h, the tear meniscus area (TMA) and CCT was measured (with optical coherence tomography) as well as tear osmolarity.

RESULTS

TMA revealed statistical differences for both lenses at 20min (p<0.001), and also at 8h (p=0.003), being greater for the C-ScL. CCT showed statistical differences for both lenses at 20min (p=0.002), and also at 8h (p=0.001), being lower for the C-ScL. Osmolarity did not reveal statistical differences at 20min (p=0.29), while it was statistically different at 8h (p=0.03), being lower for the C-ScL.

CONCLUSIONS

C-ScL lead to a lesser reduction in the TMA and a lower induced hypoxic stress than the ScL. Osmolarity levels remained within normal values across the day with no clinical difference between lenses. Both designs can represent a good optical platform for correcting presbyopia as well as protecting the ocular surface by vaulting the cornea.

Для цитирования: Lafosse Edouard, Romín Daniel Monsálvez, Esteve-Taboada José-Juan, Wolffsohn James S, Talens-Estarelles Cristian, García-Lázaro Santiago. Comparison of the influence of corneo-scleral and scleral lenses on ocular surface and tear film metrics in a presbyopic population.. Contact lens & anterior eye : the journal of the British Contact Lens Association. 2017. DOI: 10.1016/j.clae.2017.09.014.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.