MedElevator Войти в исследования
← Поиск публикаций

DOI 10.3928/1081597x-20161006-03

Медицинская библиотека · Journal of refractive surgery (Thorofare, N.J. : 1995) · 2017

Presbyopic Correction Using Monocular Bi-aspheric Ablation Profile (PresbyMAX) in Hyperopic Eyes: 1-Year Outcomes.

Chan Tommy C Y, Kwok Peter S K, Jhanji Vishal, Woo Victor C P, Ng Alex L K

СтатьяПеревод пока не подготовлен

Аннотация

PURPOSE: To present the 1-year outcomes of combining monocular bi-aspheric ablation profile and contralateral monofocal LASIK in hyperopic patients with presbyopia.

METHODS

In this retrospective case series, 36 consecutive patients (72 eyes) who underwent simultaneous bi-aspheric ablation (PresbyMAX: SCHWIND Eye-Tech-Solutions GmbH and Co KG, Kleinostheim, Germany) in the non-dominant eye and monofocal regular LASIK in the dominant eye for correction of hyperopia and presbyopia were reviewed for 1 year. Binocular uncorrected distance (UDVA), near (UNVA), corrected distance (CDVA), and distance corrected near (DCNVA) visual acuity and manifest refraction were analyzed postoperatively.

RESULTS

At 1 year, the mean binocular UDVA improved significantly from 0.26 ± 0.25 to 0.039 ± 0.088 logMAR (P < .001). Binocular UNVA also improved from 0.73 ± 0.30 to 0.10 ± 0.22 logRAD (P < .001). Eighty-seven percent of patients achieved UDVA of 20/25 or better and 90% had UNVA of J3 or better. Simultaneous binocular distance and near vision of 20/25 and J2 or better was achieved in 70%. Only 17% of patients had a binocular DCNVA of J2 or better. No patient suffered from a loss of 2 lines of CDVA. Refractive stability was achieved for both eyes from 1 month postoperatively. The re-treatment rate was 14% for improvement of near vision within 6 months to 1 year.

CONCLUSIONS

Presbyopic correction using monocular PresbyMAX combined with monofocal regular LASIK in the fellow eye is safe and acceptable in hyperopic patients. [J Refract Surg. 2017;33(1):37-43.].

Для цитирования: Chan Tommy C Y, Kwok Peter S K, Jhanji Vishal, Woo Victor C P, Ng Alex L K. Presbyopic Correction Using Monocular Bi-aspheric Ablation Profile (PresbyMAX) in Hyperopic Eyes: 1-Year Outcomes.. Journal of refractive surgery (Thorofare, N.J. : 1995). 2017. DOI: 10.3928/1081597x-20161006-03.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.