International journal of ophthalmology · 2016
Assessment of contrast sensitivity loss after intrastromal femtosecond laser and LASIK procedure.
СтатьяНазвание и аннотация: Перевод пока не подготовлен
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Mai Elsa L C, Lian Ie-Bin, Chang David C K
Аннотация
AIM: To assess the loss of contrast sensitivity (CS) function for INTRACOR or intrastromal femtosecond laser presbyopia procedure to conventional LASIK procedures.
METHODS: Patients were recruited from a refractive surgery center for either INTRACOR or conventional LASIK. INTRACOR was performed on 8 eyes and LASIK was performed for 40 eyes in an overlapping period. Pre-operative evaluation and post-operative follow up for up to three months was done. Drops of CS in 4 spatial frequency (3 cpd, 6 cpd, 12 cpd and 18 cpd) right before and 3mo after the surgery were compared by Wilcoxon signed ranks test.
RESULTS: For INTRACOR, CS threshold showed significant drop at both glare and non-glare condition, the drop was seen in all 4 spatial frequency. The averaged loss over the 4 spatial frequencies 3mo after surgery was 1.18 for non-glare and 0.71 for glare. For LASIK the CS threshold drop was most significant in 12 cpd for glare.
CONCLUSION: INTRACOR procedure produces a gain of near vision for presbyopia patients but also introduces a high lost of contrast sensitivity plus worsen of vision quality. Pre-surgical patient selection and advise should be given with specific regards to night driving and glare conditions.
METHODS: Patients were recruited from a refractive surgery center for either INTRACOR or conventional LASIK. INTRACOR was performed on 8 eyes and LASIK was performed for 40 eyes in an overlapping period. Pre-operative evaluation and post-operative follow up for up to three months was done. Drops of CS in 4 spatial frequency (3 cpd, 6 cpd, 12 cpd and 18 cpd) right before and 3mo after the surgery were compared by Wilcoxon signed ranks test.
RESULTS: For INTRACOR, CS threshold showed significant drop at both glare and non-glare condition, the drop was seen in all 4 spatial frequency. The averaged loss over the 4 spatial frequencies 3mo after surgery was 1.18 for non-glare and 0.71 for glare. For LASIK the CS threshold drop was most significant in 12 cpd for glare.
CONCLUSION: INTRACOR procedure produces a gain of near vision for presbyopia patients but also introduces a high lost of contrast sensitivity plus worsen of vision quality. Pre-surgical patient selection and advise should be given with specific regards to night driving and glare conditions.