Assessment of contrast sensitivity loss after intrastromal femtosecond laser and LASIK procedure.

Mai Elsa L C, Lian Ie-Bin, Chang David C K

СтатьяПеревод пока не подготовлен

Аннотация

AIM: To assess the loss of contrast sensitivity (CS) function for INTRACOR or intrastromal femtosecond laser presbyopia procedure to conventional LASIK procedures.

METHODS

Patients were recruited from a refractive surgery center for either INTRACOR or conventional LASIK. INTRACOR was performed on 8 eyes and LASIK was performed for 40 eyes in an overlapping period. Pre-operative evaluation and post-operative follow up for up to three months was done. Drops of CS in 4 spatial frequency (3 cpd, 6 cpd, 12 cpd and 18 cpd) right before and 3mo after the surgery were compared by Wilcoxon signed ranks test.

RESULTS

For INTRACOR, CS threshold showed significant drop at both glare and non-glare condition, the drop was seen in all 4 spatial frequency. The averaged loss over the 4 spatial frequencies 3mo after surgery was 1.18 for non-glare and 0.71 for glare. For LASIK the CS threshold drop was most significant in 12 cpd for glare.

CONCLUSION

INTRACOR procedure produces a gain of near vision for presbyopia patients but also introduces a high lost of contrast sensitivity plus worsen of vision quality. Pre-surgical patient selection and advise should be given with specific regards to night driving and glare conditions.

Для цитирования: Mai Elsa L C, Lian Ie-Bin, Chang David C K. Assessment of contrast sensitivity loss after intrastromal femtosecond laser and LASIK procedure.. International journal of ophthalmology. 2016. DOI: 10.18240/ijo.2016.12.16.
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.