Diagnostic Value of the Early Heart-to-Mediastinum Count Ratio in Cardiac 123I-mIBG Imaging for Parkinson's Disease.

Frantellizzi Viviana, Lavelli Valentina, Ferrari Cristina, Sardaro Angela, Farcomeni Alessio, Pacilio Massimiliano, Borrazzo Cristian, Pani Roberto, Rubini Giuseppe, Vincentis Giuseppe De

СтатьяПеревод пока не подготовлен

Аннотация

BACKGROUND

Early diagnosis of Parkinson's disease (PD) is of primary importance. The delayed (3-4 h after injection) Iodine-123-Metaiodobenzylguanidine (123I-mIBG) scintigraphy has been proven to be effective in early differential diagnosis for Lewy body disease. But early imaging (15-30 min after injection) has only been marginally studied for its possible diagnostic role. In this prospective study, a threshold for the early Heart-to-Mediastinum (H/M) count ratio has been investigated, obtaining a diagnostic accuracy analogous to conventional, delayed imaging.

METHODS

One hundred and eight patients with suspected Parkinson's disease (PD) were acquired after 15 and 240 minutes from the injection of 150-185 MBq of 123I-mIBG. The early and late H/M (He/Me and Hl/Ml) were evaluated by drawing Region-of-Interests on the heart and the upper half of the mediastinum. Optimal threshold (Youden index) and overall predictive performance were determined by receiver operating characteristic curve, classifying tentatively patients having an Hl/Ml lower than 1.6 as suffering from PD.

RESULTS

He/Me was not significantly different from Hl/Ml (p-value=0.835). The Area-under-curve was 0.935 (95%CI: 0.845-1.000). The He/Me optimal threshold was 1.66, with sensitivity, specificity, and diagnostic accuracy of 95.5%, 85.7 and 90.7% respectively.

CONCLUSION

The He/Me Ratio is almost as accurate as the widely used delayed 123I-mIBG imaging, reducing the burden of delayed imaging but preserving the diagnostic accuracy of the method. Moreover the differential diagnosis in Parkinson's disease can be made in just 25 minutes against the 4 hours currently needed, lowering costs of the healthcare system and improving patients compliance.

Для цитирования: Frantellizzi Viviana, Lavelli Valentina, Ferrari Cristina, Sardaro Angela, Farcomeni Alessio, Pacilio Massimiliano, Borrazzo Cristian, Pani Roberto, Rubini Giuseppe, Vincentis Giuseppe De. Diagnostic Value of the Early Heart-to-Mediastinum Count Ratio in Cardiac 123I-mIBG Imaging for Parkinson's Disease.. Current radiopharmaceuticals. 2021. DOI: 10.2174/1874471013999200727211633.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.