Predicting Accommodative Response Using Paraxial Schematic Eye Models.

Ramasubramanian Viswanathan, Glasser Adrian

СтатьяПеревод пока не подготовлен

Аннотация

PURPOSE: Previous ultrasound biomicroscopy (UBM) studies showed that accommodative optical response (AOR) can be predicted from accommodative biometric changes in a young and a pre-presbyopic population from linear relationships between accommodative optical and biometric changes, with a standard deviation of less than 0.55D. Here, paraxial schematic eyes (SE) were constructed from measured accommodative ocular biometry parameters to see if predictions are improved.

METHODS

Measured ocular biometry (OCT, A-scan, and UBM) parameters from 24 young and 24 pre-presbyopic subjects were used to construct paraxial SEs for each individual subject (individual SEs) for three different lens equivalent refractive index methods. Refraction and AOR calculated from the individual SEs were compared with Grand Seiko (GS) autorefractor measured refraction and AOR. Refraction and AOR were also calculated from individual SEs constructed using the average population accommodative change in UBM measured parameters (average SEs).

RESULTS

Schematic eye calculated and GS measured AOR were linearly related (young subjects: slope = 0.77, r = 0.86; pre-presbyopic subjects: slope = 0.64, r = 0.55). The mean difference in AOR (GS - individual SEs) for the young subjects was -0.27D and for the pre-presbyopic subjects was 0.33D. For individual SEs, the mean ± SD of the absolute differences in AOR between the GS and SEs was 0.50 ± 0.39D for the young subjects and 0.50 ± 0.37D for the pre-presbyopic subjects. For average SEs, the mean ± SD of the absolute differences in AOR between the GS and the SEs was 0.77 ± 0.88D for the young subjects and 0.51 ± 0.49D for the pre-presbyopic subjects.

CONCLUSIONS

Individual paraxial SEs predict AOR, on average, with a standard deviation of 0.50D in young and pre-presbyopic subject populations. Although this prediction is only marginally better than from individual linear regressions, it does consider all the ocular biometric parameters.

Для цитирования: Ramasubramanian Viswanathan, Glasser Adrian. Predicting Accommodative Response Using Paraxial Schematic Eye Models.. Optometry and vision science : official publication of the American Academy of Optometry. 2016. DOI: 10.1097/opx.0000000000000868.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.