PURPOSE: To evaluate the influence of the number of concentric zones of a center-near bifocal optics on the subjective quality of vision.

METHODS

Twenty-two subjects scored with a five-item continuous grading scale the quality of vision of calculated images (i.e., three high-contrast 20/50 letters) viewed through their best sphero-cylindrical correction and a 3-mm pupil to limit the impact of their aberrations. Through-focus images were calculated from -4 to +2 diopters (D), each 0.25 D, in the presence of center-near bifocal optics (Add 2.5 D) varying by their number of concentric zones (from 2 to 20).

RESULTS

To compare the results obtained with these profiles, we calculated the area under the (through-focus) curve (AUC) higher than 2 out of 5 (i.e., limit between a poor and a fair image quality, considered as the limit of acceptability). This value was normalized by the naked eye condition and divided into distance, intermediate, and near AUC. The results showed large interindividual variations. Distance AUC remained quite similar whatever the profile, near AUC decreased with the number of concentric zones, and intermediate AUC rose with the number of concentric zones. With 10 and 20 concentric zones, diffraction phenomenon induced constructive interferences at intermediate proximities and destructive interferences at distance and near proximities.

CONCLUSIONS

To balance distance, intermediate, and near quality of vision, a number of zones between 8 and 10 should be chosen. If the subject does not need intermediate quality of vision, then a profile with two to five zones should be favored.

Для цитирования: Legras Richard, Rio David. Effect of Number of Zones on Subjective Vision in Concentric Bifocal Optics.. Optometry and vision science : official publication of the American Academy of Optometry. 2015. DOI: 10.1097/opx.0000000000000713.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.